Closed andimik closed 7 years ago
Thanks, fixed!
Are you sure?
Because the word "protection" (lower case) is not printed out, not even with -v -f
.
So I fear you've modified the wrong file.
I guess it should be fig0_1.cpp
, line 86 and 89.
Yeah, I did that a bit too quickly and fixed the printout for the statistics file only. Now it should be ok.
Ein Grüezi in die Schweiz,
Statistics File? Is this a new feature? How to get that? Not found a description on http://wiki.opendigitalradio.org/Etisnoop
Meaning the wiki is outdated ;-)
Yes, nor have I written anything to the README :-) It's the -s option, to be combined with https://github.com/mpbraendli/mmbtools-aux/tree/master/etisnoop-stat-server
Seems you have always to add 1 in order to get the correct EEP protection level for FIG (only there!).
There is no EEP 0-A and no EEP-0-B. In my example below I wrote this file:
test_protlev.txt
And the CUs are wrong, for 96 kBit 1A is 144 CU, 2A is 96, 3A is 72, 4A is 48, and so on.