Review precaster's details at south wall beam #101

Closed theoryshaw closed 4 years ago

theoryshaw commented 4 years ago

Details: CTR_closed_cannery district - eau claire\Building Products\03 - Concrete\03 40 00 Precast Concrete\20191126 - from Precast Eng - Details at Precast Beam - for review

from precast supplier

Here is the connection design for the exterior LB beam along grid 6 at the knock-out cmu wall. Please review and comment if needed.

Take note of the top of CIP pier elevation and the cip blockout to accommodate beam height and beam bearing distances.

Also note the required 1” gap joint from beam end to cip wall edge. All this maintains the 24’-0” clear i.s. to i.s. at the temporary cmu wall opening.

theoryshaw commented 4 years ago

@lcpt i'll take an initial stab at reviewing.

theoryshaw commented 4 years ago

@lcpt

Here's my review... CTR_closed_cannery district - eau claire\Building Products\03 - Concrete\03 40 00 Precast Concrete\20191127 - from ARCH to STRUCT - reviewed precast beam details\20191127 - precast beam at south wall - OD reviewed.pdf

If you can, please take a quick review as well.

Thanks, Ryan

lcpt commented 4 years ago

OK. I'll do it now.

lcpt commented 4 years ago

Here's mine:

_CLOSED_Cannery District - Eau Claire/Building Products/03 - Concrete/03 40 00 Precast Concrete/20191127 - from STRUCT to ARCH - reviewed precast beam details