3/4" grade B interior plywood with Class B flame spread
oriented horizontally, fastened top and bottom (4ft+/-) O.C. to horizontal 'C' girts.
vertical studs are NOT planned at the 8ft edges of the sheathing.
Exposed Fasteners
1b - Resin Panel at certain parapet conditions.
Stonewood Panel
162S125-33 (1-5/8" C stud w/ 1.25 flange by 33 mils - no punchouts allowed)
horizontal galvanized girts attached to column stubs through metal roofing.
@kraut34 we had to push the exterior plywood up to 7/8 for rigidity. It was either that or go with 3/4" plywood with vertical coil straps every 24" between plywood.
Thanks @andyeck1, for the chat...
Here's how the composition of the Resin wall is shaping up...