Closed suseela22 closed 3 months ago
@Surinarayanan please have vijay or vikram check the issue and report the findings
@ClementJosh21 need details on the fix added.
RCA
if we give the wrong data time format (20/10/2001 00:00) for DATETIME, perviously we skip that rows and proceed, that ingestion gets successful but the data is not ingest
Fix details
now throw the exception while data type format mismatch for DateTime
It throws the exception for mismatched date time format. Tested in 146 server
This fixes are ready and verified. This is planned to be avaialable in version 2024.01.x
@suseela22
The issue is fixed in the latest version 2024.01.x which is updated in the region given to implemention team. Kindly check and provide closure
Working as expected
In Job status the status is showing completed message but data is not Ingested.