I noticed that the mod meter goes from green to red one segment earlier than the signal meter does.
In order to visually line up both meters evenly, I changed the criterion for the mod meter from 53 to 54 (in code line 3293 - 3295) and that works, however I don't know whether that would screw up something else :-)
I noticed that the mod meter goes from green to red one segment earlier than the signal meter does. In order to visually line up both meters evenly, I changed the criterion for the mod meter from 53 to 54 (in code line 3293 - 3295) and that works, however I don't know whether that would screw up something else :-)