Closed psyciknz closed 4 years ago
If you arm from paradox keyboard then it is impossible.
Ahh, keyboard or remote. So if there was a bypass you cxan only arm via PAI (so in my case via homekit).
How do you tell pai to bypass a sensor? Is it part of the arm command, or do you set the sensor as bypassed, then arm it?
See mqtt section in wiki. bypassing is there. It is a separate command.
Ok I see this:
paradox/control/zones/name allow setting some zone properties where name identifies the zone. If the name is all, all zones will be updated. The payload can have the values bypass and clear_bypass.
But is that something I set before the partition is armed.....or can I set it after arming. It just says what I can do, not how I can use it.
I do not know about SP/MG. But in EVO you cannot bypass a zone in an armed partition.
This issue has been automatically marked as stale because it has not had recent activity. It will be closed if no further activity occurs. Thank you for your contributions.
Alarm system
Spectra SP6000 via ip150
Environment
Linux X86 Docker
Git branch
Old master
Question
Is it possible to bypass sensors. I'd assume for a workflow it would be set before the panel is armed.