Thermocouple connector milled slots close to footprint edge #111

Closed charlespax closed 9 years ago

charlespax commented 9 years ago

I think there is potential for the thermocouple connector milled slots to cut too much into the footprint of connector and break the connection. It really depends on how everything is soldered together. This may not even be the final connector or footprint. we should keep an eye on this.

screen shot 2014-12-23 at 12 40 28

samchoy88 commented 9 years ago

Just got the PCB factory feedback, the minimum milling slot is 0.8mm They do not approve the design. Need to modify on Rev 0.9

Will modify this milling slot and the pad in library.

charlespax commented 9 years ago

Slot size in new issue https://github.com/PaxInstruments/t400-electronics/issues/112. Closed

charlespax commented 9 years ago

For reference, here are the pads with the larger milled slots. screen shot 2014-12-24 at 09 41 08

charlespax commented 9 years ago

This didn't seem to be a problem in Electronics version 0.9. Closing issue.