Closed tavaughan closed 4 months ago
Thanks David, yes I got that too. It should be fixed in #53 (though I also added calibration data to the Detectors in the lab since, so that might also appear to "fix" your issue)
Closing in favour of #53 (sorry about the mess, but I can't seem to easily change this request to point to a different remote from my NRC-related github account)
I got the above error when trying to 'Connect' my detector. Here is the error message in the console: ERROR:src.common.status_message_source:source_label='connector' severity='error' message='No calibration available for detector d at resolution 640x480. No intrinsics will be set.' timestamp_utc_iso8601='2024-06-25T17:16:06.551 086' ERROR:src.common.status_message_source:source_label='connector' severity='error' message='Exception occurred in connector loop: 1 validation error for GetCalibrationResultRequest\nresult_identifier\n none is not an allowed val ue (type=type_error.none.not_allowed)' timestamp_utc_iso8601='2024-06-25T17:16:08.553569'