Closed HaihuiZhang closed 5 years ago
ESPEI-datasets/AL-NI/input-json/FCC_L12/AL-NI-HM-FCC_L12-Shunli DFT calculations (2010).json
If you look in the figure captions, e.g. in Figure 7, the Ni3Al data is reported with units J/mol-formula (per unit cell of Ni3Al, with 4 atoms). ESPEI single phase data always must be J/mole-atom, so the Ni3Al dataset is 1/4 the values in the figures.
I got it. I am all gratitude.
I found that the input data for Ni3Al on github is different from the reference of "Shunli DFT calculations (2010)". Is the reference "First-principles thermodynamics from phonon and Debye model: Application to Ni and Ni3Al"? The HM, SM, CPM data obtained from Fig7 and 8 are not the same as the data on github. For example, the HM value at 1615K, github is 39428.25, while in the literature is 157430. What caused it? Do we need a numerical conversion?