Open MattCummings0517 opened 1 year ago

MattCummings0517 commented 1 year ago

Currently the burnwire is activated when a battery cell drops below a configurable level. A single bad reading or error may cause erroneous activation. Bad readings have been seen occasionally on development boards. The software should double or triple check any reading that is low enough to trigger the burnwire.