This is the log from the pulse eight USB adapter we recently bought.
Wondering what is the low-level ACK sent from TV for the CEC POLL message "F0" - I have highlighted it in red.
Is it possible to mimic the ACK sent by TV.
cec-client /dev/ttyACM0
No device type given. Using 'recording device'
CEC Parser created - libCEC version 3.0.1
opening a connection to the CEC adapter...
DEBUG: [ 0] Broadcast (F): osd name set to 'Broadcast'
DEBUG: [ 1] connection opened, clearing any previous input and waiting for active transmissions to end before starting
DEBUG: [ 1] communication thread started
DEBUG: [ 11] turning controlled mode on
NOTICE: [ 32] connection opened
DEBUG: [ 32] processor thread started
DEBUG: [ 32] << Broadcast (F) -> TV (0): POLL
TRAFFIC: [ 32] << f0
DEBUG: [ 32] setting the line timeout to 3
DEBUG: [ 68] >> POLL sent
DEBUG: [ 68] TV (0): device status changed into 'present'
DEBUG: [ 68] << requesting vendor ID of 'TV' (0)
TRAFFIC: [ 68] << f0:8c
TRAFFIC: [ 266] >> 0f:87:00:e0:91
DEBUG: [ 266] TV (0): vendor = LG (00e091)
DEBUG: [ 266] >> TV (0) -> Broadcast (F): device vendor id (87)
DEBUG: [ 266] expected response received (87: device vendor id)
DEBUG: [ 266] replacing the command handler for device 'TV' (0)
DEBUG: [ 266] TV (0): CEC version 1.3a
DEBUG: [ 266] TV (0): menu language set to 'eng'
NOTICE: [ 266] registering new CEC client - v3.0.1
Any suggestions/comments would be helpful.
Thanks in advance.
Hi,
Hello,
This is the log from the pulse eight USB adapter we recently bought.
Wondering what is the low-level ACK sent from TV for the CEC POLL message "F0" - I have highlighted it in red.
Is it possible to mimic the ACK sent by TV.
cec-client /dev/ttyACM0 No device type given. Using 'recording device' CEC Parser created - libCEC version 3.0.1 opening a connection to the CEC adapter... DEBUG: [ 0] Broadcast (F): osd name set to 'Broadcast' DEBUG: [ 1] connection opened, clearing any previous input and waiting for active transmissions to end before starting DEBUG: [ 1] communication thread started DEBUG: [ 11] turning controlled mode on NOTICE: [ 32] connection opened DEBUG: [ 32] processor thread started DEBUG: [ 32] << Broadcast (F) -> TV (0): POLL TRAFFIC: [ 32] << f0 DEBUG: [ 32] setting the line timeout to 3 DEBUG: [ 68] >> POLL sent DEBUG: [ 68] TV (0): device status changed into 'present' DEBUG: [ 68] << requesting vendor ID of 'TV' (0) TRAFFIC: [ 68] << f0:8c TRAFFIC: [ 266] >> 0f:87:00:e0:91 DEBUG: [ 266] TV (0): vendor = LG (00e091) DEBUG: [ 266] >> TV (0) -> Broadcast (F): device vendor id (87) DEBUG: [ 266] expected response received (87: device vendor id) DEBUG: [ 266] replacing the command handler for device 'TV' (0) DEBUG: [ 266] TV (0): CEC version 1.3a DEBUG: [ 266] TV (0): menu language set to 'eng' NOTICE: [ 266] registering new CEC client - v3.0.1
Any suggestions/comments would be helpful. Thanks in advance.