add SMR capacities build between 1990-2020
#22
Open
lindnemi
opened
4 months ago
lindnemi
commented
4 months ago
Observation:
SMR capacity stays constant
Explanation:
lifetime in technology data is 30 years (could cover 2020-2050) and most SMR will probably be built in 2020 -- in 2050 it's probably of no/limited use
But in real life some SMR would be built in 1990-2020 and we don't take account of this
Fix:
add SMR capacities built between 1990-2020 and ensure that they are phased out correctly
Observation:
Explanation:
Fix: