Klipper console error: Unknown command:"G17" with Q1 Pro #15

Closed TinkerBarn closed 3 weeks ago

TinkerBarn commented 1 month ago

I get with different STL's after slicing in QIDI Studio Version 1.9.7.52 in Klipper console the error: Unknown command:"G17" Today also one error: Unknown command:"T8" Use Q1 Pro with Firmware V4.4.24

The 3D prints looks always ok. I can't see any issue. But this error message should not be there.

00:08:01 File opened:.cache/Switch Mount+.stl.gcode Size:1368637 00:08:01 File selected 00:08:04 // Run Current: 0.80A Hold Current: 0.80A 00:08:05 // Run Current: 1.00A Hold Current: 1.00A 00:08:06 // Run Current: 0.90A Hold Current: 0.90A 00:08:07 // Run Current: 1.00A Hold Current: 1.00A 00:08:08 // Run Current: 0.80A Hold Current: 0.80A 00:08:09 // Run Current: 1.00A Hold Current: 1.00A 00:08:35 // Run Current: 1.07A Hold Current: 1.07A 00:08:36 // Run Current: 1.07A Hold Current: 1.07A 00:11:19 echo: Nozzle cleared 00:12:22 echo: Nozzle cooled 00:12:25 // Run Current: 0.80A Hold Current: 0.80A 00:12:31 // Run Current: 1.00A Hold Current: 1.00A 00:12:32 // Run Current: 0.90A Hold Current: 0.90A 00:12:35 // Run Current: 1.00A Hold Current: 1.00A 00:12:36 // Run Current: 0.80A Hold Current: 0.80A 00:12:37 // Run Current: 1.00A Hold Current: 1.00A 00:12:49 // Run Current: 1.07A Hold Current: 1.07A 00:12:49 // Run Current: 1.07A Hold Current: 1.07A 00:12:49 // Run Current: 1.07A Hold Current: 1.07A 00:13:15 // probe at 120.000,120.000 is z=-2.294688 00:13:18 // probe at 120.000,120.000 is z=-2.275938 00:13:20 // probe at 120.000,120.000 is z=-2.275781 00:13:23 // probe at 120.000,120.000 is z=-2.274063 00:13:26 // probe at 120.000,120.000 is z=-2.213594 00:13:26 // Probe samples exceed tolerance. Retrying... 00:13:28 // probe at 120.000,120.000 is z=-2.275625 00:13:31 // probe at 120.000,120.000 is z=-2.275938 00:13:31 // probe at 120.000,120.000 is z=-2.275938 00:13:33 // probe at 120.000,120.000 is z=-2.312188 00:13:36 // probe at 120.000,120.000 is z=-2.278281 00:13:38 // probe at 120.000,120.000 is z=-2.276406 00:13:38 // Result is z=-2.276875 00:13:38 X:120.000 Y:120.000 Z:-2.277 E:80.000 00:13:38 // Variable Saved 00:14:54 // Filament width sensor Turned On 00:14:54 // Filament width measurements cleared! 00:14:54 // Filament dia (measured mm): 1.2 00:14:55 // Variable Saved 00:14:55 // Variable Saved 00:14:55 // Variable Saved 00:14:55 // Variable Saved 00:14:55 echo: Last File: Switch Mount+.stl.gcode 00:14:55 // Hyperlapse: frames started (Cycle 3 sec) 00:15:02 **// Unknown command:"T8"** 00:15:02 // pressure_advance: 0.035000 // pressure_advance_smooth_time: 0.030000 00:16:28 **// Unknown command:"G17" 00:17:18 // Unknown command:"G17" 00:18:07 // Unknown command:"G17" 00:18:23 // Unknown command:"G17" 00:18:41 // Unknown command:"G17" 00:18:58 // Unknown command:"G17" 00:19:15 // Unknown command:"G17" 00:19:32 // Unknown command:"G17" 00:19:50 // Unknown command:"G17" 00:20:07 // Unknown command:"G17" 00:20:24 // Unknown command:"G17" 00:20:38 // Unknown command:"G17" 00:20:51 // Unknown command:"G17" 00:21:05 // Unknown command:"G17" 00:21:19 // Unknown command:"G17"**

QIDITECH commented 1 month ago

Don't worry, undefined code will be skipped and won't affect printing. Because the klipper version of Q1 is not yet compatible with G17, please ignore this error.