Vertical Y Units for Noise Measurements #22

Closed codegame closed 1 year ago

codegame commented 2 years ago

Y-axis units are currently too scarce. For the measurement of noise parameters, although there is currently dBV, it requires tedious conversion calculations, so it is necessary to use the commonly used noise measurement units (uV)rtHz and (nV)rtHz. A custom conversion function or plugin, this feature is looking forward to seeing it in the next new version, thanks.

QuantAsylum commented 1 year ago

Yes, agree and we will study. I have the same issues with the hand conversions. It's tedious.

QuantAsylum commented 1 year ago

RtHz is enabled in 1.154 (see dBV context menu) but it will take more time to get non-log Y axis

NoiseFree commented 1 year ago

Suggestion: loglog plot with linear x and y values is very readable

image

QuantAsylum commented 1 year ago

This is in 1.175. The right-side of the main plot will show volts/rthz and the left side will show dB (as today).

https://github.com/QuantAsylum/QA40x/releases/tag/1.175

NoiseFree commented 1 year ago

Thanks for the improvement!

A toggle grid setting would be the icing on the cake.