Ralim / IronOS

Open Source Soldering Iron firmware
https://ralim.github.io/IronOS/
GNU General Public License v3.0
7.28k stars 723 forks source link

Boot logo swap still shows Miniware logo for about 1/3 of a second on TS80P #1308

Closed skeeballassault closed 2 years ago

skeeballassault commented 2 years ago

Describe the bug Just got my new TS80P, and when adding a custom boot logo, the Miniware logo still shows for about a third of a second before cutting to my custom logo. Videos I've seen have shown the Miniware logo not showing up at all so that appears to be intended behavior - this isn't a world ending bug but it will certainly bother me.

To Reproduce

  1. Flash TS80P with current firmware.
  2. Flash boot logo from provided sample boot logos as indicated by the included README
  3. Boot the device. The Miniware logo shows for a short period before transitioning to my chosen boot logo. Expected behavior

    The Miniware logo is completely replaced with the logo I flashed.

Details of your device:

Additional context

Ralim commented 2 years ago

On the TS80P on later DFU versions, miniware added this to the bootup before ironos starts. So IronOS has no control over this.

The only way to remove it is to entirely replace the DFU bootloader; noting that this comes with some risk. So it is best to have a SWD programmer on hand just in case.

discip commented 2 years ago

@skeeballassault If you are brave enough to try replacing the bootloader, here is the place you should go: IronOS-dfu

So, since this is no real issue, but rather up to you being willing to replace the stock bootloader, please close this issue. 😊 thanks in advance