Open Yagoth opened 1 year ago
Hello,
TS80 is still supported, and this should not happen.
Please, do you have available any power analysis tool?
I am not entirely sure what you mean by power analysis tool. I have the USB power meter(pictured below) and a decent multi-meter. I have also confirmed that the temperature reading is accurate.
Power reading I have obtained: 4 patterns occur:
@Yagoth yes, multimeter and mostly, USB-C meter. And great, those information will be very useful.
@Ralim is currently out of the office, so he will take look on this on end of this month.
@Yagoth Is this issue still present? Have you tested the latest release?
Issue is still present, thank you for following up. I will install 2.21 when I return home from my trip.
Please try this one: https://github.com/Ralim/IronOS/releases/tag/v2.22-rc2
Describe error. My TS80 is stuck at 5V using build 2.20. It will report 9V immediately after being plugged in, but after 1 second to 5 minutes it will drop to 5v and get stuck there.
For reproduction Be using V2.20 EN Plug in TS80 Wait 1 second to 5 minutes. Switches and gets stick in 5v mode
Details of your device:.
Extra Notes: I found an old post relating to V2.10 relating to the same issue. https://github.com/Ralim/IronOS/issues/1107
Any idea on a fix? I kind of get the feeling that TS80 is not even supported at this point, given that TS80P and Pinecil is the sole market segment.
If it is no longer supported what firmware should I use?
I can confirm that I am using V2.20 not the stock firmware. Images attached.