Rat-OS / RatOS-configuration

The RatOS modular klipper configuration
146 stars 134 forks source link

Hotend / Extruder configuration not working for PT1000 sensor #275

Open romarysonrier opened 2 months ago

romarysonrier commented 2 months ago

What happened

Currently the only settings available extruder temperature sensor is "Hotendthermistor".

But it doesn't work when using PT1000, as it is not setting the proper klipper configuration.

On Octopus Pro, for [extruder] , It is setting :

heater_pin: PA0 sensor_type: PT1000 sensor_pin: PF4 pullup_resistor: 3700

what is not correct.

what's more "pullup_resistor:3700" prevent any override in printer.cfg because klipper doesn't support this setting for MAX31865

What did you expect to happen

On Octopus Pro, for [extruder], It should set :

sensor_type: MAX31865 sensor_pin: PF8 spi_software_sclk_pin: PA5 spi_software_mosi_pin: PA7 spi_software_miso_pin: PA6 spi_speed: 4000000 rtd_nominal_r: 1000 rtd_reference_r: 4300 rtd_num_of_wires: 2 rtd_use_50Hz_filter: True

How to reproduce

Vcore 3 Octopus Pro V1.1 All latest version

Additional information

I would suggest to add in the UI a hotend tempreratur sensor selectbox , to allow the user to chosse the proper sensor chip. And then it would allow to restrict the current Thermistor select box only to valid values for the selected chip.

kmarty commented 2 months ago

Connecting PT1000 to TH0 pin, i.e. the same way as NTC thermistor, is perfectly valid option. The pullup_resistor might be off, since TH0 (PF4) has 4.7k pull-up thus this setting is unnecessary since value 4700 is Klipper default.

But the part:

sensor_type: PT1000
sensor_pin: PF4

is ok. It is one of the options how to use PT1000 (not PT100, which unconditionally requires MAX chip. For PT1000, the MAX chip is just optional)

HelgeKeck commented 2 months ago

the max chip creates mostly issues with klipper for no real benefit for the user. jsut connect it according to the ratos documentation to the normal th connector and it will work just fine

HelgeKeck commented 2 months ago