Closed russell-taylor closed 3 years ago
Make this an option, but what should its default value be?
Dave and Jane say to always include them with no option not to. The overall terms are designed for the inside terms to balance the outside terms, so not having them will not follow the Lennard-Jones-like curve
Probe radius defaults to 0.25 Angstroms and is used in Probe to determine the partial and total solvent accessible surface and to determine if points are near. For Reduce, it is used to in a function that determines whether atoms are bumping (CollectBumping) but this function is never called; it is also added to the atom radii to determine which atoms are nearby and should be checked.
In Reduce, the probe radius defaults to 0, which means that it is hit or miss whether further neighbor atoms will be considered (can depend on maximum radius of all atoms found in some cases), which means that not all near-miss dots are considered.
The time taken for reduce -FLIP -RADIUS#.# varies as follows:
Radius 0.0 (default): 2m3.6s Radius 0.25 (Probe default): 2m45.7s Radius 0.5: 3m27.9s
Added to main repository, including fixes for bugs found when implementing.
Paper says that probe but not reduce gives favorable scores for near contacts