Issue when running prism input file with multiple synthetic filters #507

Closed rebekah9969 closed 3 years ago

rebekah9969 commented 3 years ago

I am running snlc_sim.exe SIMGEN_WFIRST_Allz_SNIA.input

in

/project2/rkessler/SURVEYS/WFIRST/USERS/rhounsell/CYCLE8/PRISM/APR2021/FULL

and am receiving the error

Begin Generating Lightcurves.   

Found Max dN/dz * wgt = 9.037781e+05 at z = 0.997

|```````|
<| o\ /o |>
| ' ; ' |
| | ABORT program on Fatal Error. | |' '| |
| `---' |
____
/

FATAL ERROR ABORT called by SIMLIB_TAKE_SPECTRUM NOBS=13496 exceeds MXOBS_SIMLIB=10000 Check number of synthetic bands from SPECTROGRAPH

please advise

Thank you

RickKessler commented 3 years ago

MXOBS_SIMLIB -> 15,000 (was 10k). However, the real could be that the Roman SIMLIB file now includes 3 years instead of 2 years ?