grace-ac commented 6 years ago

So, everything has worked great- I had no issue finding the RAW files in the downloads "Archive" folder today.

However, I'm at Step 3b: Clean Dilution Curve Data, and I don't know what is wrong. All the windows are blank...? capture1

yaaminiv commented 6 years ago

Opp, I think you're following an old version of the protocol! Repeat Step 2d (I revised it yesterday so you wouldn't encounter your specific issue).

yaaminiv commented 6 years ago

@grace-ac Did that ^ work?

grace-ac commented 6 years ago

I haven't tried it yet - I'll be back in lab on Monday afternoon to test it out! sorry if you're waiting on it :(

yaaminiv commented 6 years ago

No worries! Just wanted to make sure I wasn't missing anything.

grace-ac commented 6 years ago

This happened after re-doing 2d:

capture

yaaminiv commented 6 years ago

That's odd! Didn't happen to me on the same machine you're using when I tried it out. What happens when you press cancel? I don't understand what error it's seeing. Any suggestions @emmats ?

grace-ac commented 6 years ago

I just pressed cancel, and my screen looks exactly how it does in the original screenshot of this issue

yaaminiv commented 6 years ago

Huh...what does it look like when you press OK?

grace-ac commented 6 years ago

capture

yaaminiv commented 6 years ago

It seems like you kept all of the previously imported transitions before you redid 2d! Try deleting absolutely everything from that lefthand window and re-importing the transition list.

emmats commented 6 years ago

Let me know if you still need my input.

grace-ac commented 6 years ago

I restarted from the beginning and still got the error.

Things look much better though, after clicking, "OK" and I'm currently working on Step 3b.

yaaminiv commented 6 years ago

@emmats do you know what could be causing this error? I exported the transition list from Skyline itself.

@grace-ac You should open up the transition list and make sure the transitions in your Skyline document are the same ones in the transition list you're importing.

grace-ac commented 6 years ago

I went through and I matched the numbers on the list to those in Skyline doc. I just highlighted the first three to show what numbers I was matching. capture capture1

All of the ones in Skyline Document had a match in the original document. The only ones that weren't in the Skyline doc were the ones that were labeled "peptides" rather than a number. capture2

yaaminiv commented 6 years ago

AH those are the PRTC peptides! I think I know what's causing the error so I can fix that for you. It won't affect any of your downstream analyses.

You can also click on the plus signs to expand the protein and see the peptides/transitions associated with it

grace-ac commented 6 years ago

Okay - I clicked the plus signs and they all match! woo!

Let me know when you fix whatever is causing the error and i'll re-do it!

yaaminiv commented 6 years ago

In the transition list, what would happen if you removed the space between PRTC and peptides, or got rid of that phrase entirely (keeping the other content in that row)?

grace-ac commented 6 years ago

I tried both suggestions, and both resulted in the same error.

emmats commented 6 years ago

I've never seen this error before so I can't really weigh in on what is going wrong. If you can't figure it out, I can probably stop by tomorrow afternoon or Monday.

grace-ac commented 6 years ago

I realize that you've been gone @yaaminiv , but I tried it again, because earlier in this thread you said you were going to fix something - thought I'd see if anything has changed.

Error happened again. capture

Would it have anything to do with the fact that I'm using Excel? capture-o1

kubu4 commented 6 years ago

What is the full error message from the screenshot @grace-ac posted in this comment: https://github.com/RobertsLab/project-oyster-oa/issues/27#issuecomment-337018610

grace-ac commented 6 years ago

I just updated my comment @kubu4 is that what you are looking for?

kubu4 commented 6 years ago

Nope. The error messages are truncated and can't be read. Need to be able to read the entire message for each line.

yaaminiv commented 6 years ago

I don't think it's an Excel issue! I think it's some sort of problem with Skyline where it can't recognize the peptides from the transition list because the retention times in the transition list do not align with what's in the library...? I'm still working on it, but this issue won't affect anything in the SRM protocol since I haven't dealt with my PRTC peptides yet.

grace-ac commented 6 years ago

That's as much as I could get. capture

Not really sure I understand what's happening - whether I should continue with the protocol or wait for you to investigate things @yaaminiv

yaaminiv commented 6 years ago

@grace-ac Continue!! It's possibly over my head as well so don't wait for me.

kubu4 commented 6 years ago

For kicks @grace-ac , when that line is highlighted, can you copy it (right-click or ctrl-c), and then paste in a text editor for viewing?

grace-ac commented 6 years ago

@kubu4 No, but I could hold the mouse over and read the remaining words: "match the tolerance on the Instrument tab of the Transition Settings."

Same for all of them.

yaaminiv commented 6 years ago

@grace-ac Hold up! Continue with 2e, then retry 2d. I have a hunch that after changing your transition settings, you'll be able to import everything

grace-ac commented 6 years ago

Same error. The transition settings were already set according to your protocol from my previous attempts

yaaminiv commented 6 years ago

Darn. I'm not sure what it is so I'll play around with it tomorrow, but again, it won't affect anything else in that protocol

grace-ac commented 6 years ago

Cool beans - I shall continue!

grace-ac commented 6 years ago

3b is where I'm stuck - which is where I believe I started this whole issue in the first place. capture

Does not look like your screenshot for Step 3b: capture1

yaaminiv commented 6 years ago

Ah! Instead of clicking on the protein name, you want to click on the peptide (i.e. the things with the green dots next to them)

grace-ac commented 6 years ago

So, am I comparing the peptide retention time to the average SRM retention time? capture

yaaminiv commented 6 years ago

Yup! You compare the average retention time with the retention times in the Skyline document. The correct peak will have all three transition fragments.

yaaminiv commented 6 years ago

@grace-ac Do you think you can create a new issue with the Skyline error message you keep getting? I want to address the other questions in this issue and close it out, then refer emma to the new issue you'll create!

yaaminiv commented 6 years ago

Resolved issues at 3b, but not the import issue at 2d. @grace-ac will create a new issue and I will continue the discussion there.