SBNSoftware / sbndcode

11 stars 44 forks source link

G4 fcl using Ellipsoidal Modified Box Recombination Model for 2024A Calibration Production #450

Closed wjdanswjddl closed 6 months ago

wjdanswjddl commented 6 months ago

Add G4 fcl using the ellipsoidal modified box recombination model for the upcoming 2024A production. This fcl will be used to create samples for recombination studies. Below fhicl-dump outputs shows the UseEllipsModBoxRecomb and UseModBoxRecomb parameters changed compared to the nominal fcl.

-bash-4.2$ fhicl-dump g4_sce_dirt_filter_lite_recomb_ellips.fcl | grep Box
      EllipsModBoxA: 9.06e-1
      EllipsModBoxB: 2.03e-1
      EllipsModBoxR: 1.25
      ModBoxA: 9.3e-1
      ModBoxB: 2.12e-1
      UseEllipsModBoxRecomb: true
      UseModBoxRecomb: false
-bash-4.2$ fhicl-dump g4_sce_dirt_filter_lite.fcl | grep Box
      EllipsModBoxA: 9.06e-1
      EllipsModBoxB: 2.03e-1
      EllipsModBoxR: 1.25
      ModBoxA: 9.3e-1
      ModBoxB: 2.12e-1
      UseEllipsModBoxRecomb: false
      UseModBoxRecomb: true