Site EUI (kBtu/ft²) & Source EUI (kBtu/ft²) fields are not imported with autoimport from ESPM #1707
All the fields in the ESPM report template would be imported into SEED via the new Import Portfolio Manager Data, which allows the user to log into their ESPM account and pick the report to download data from
Actual Behavior
In the test ESPM account I set up, all the fields except Site EUI (kBtu/ft²) & Source EUI (kBtu/ft²) were imported. It could have to do with the units?
From the LBNL ESPM test account that I set up, I imported data from the "Data Request:SEED City Test Report April 24 - Test 2" under "SEED City Test Report".
The 4 records imported properly into SEED
However, when I compare, field by field, the data imported into SEED vs the data in the file downloaded from ESPM, two fields are missing from the SEED import --
Site EUI (kBtu/ft²)
Source EUI (kBtu/ft²)
Here is the mapping for those two fields
In the Inventory List, View by Property, if I select "Only Show Populated Columns" the program reports back that it has 32 populated columns
If I look at Property List Settings, the two fields called Site EUI and Source EUI (no units) were not selected as populated columns (even though 2 of the records have data).
If I select those two fields to see if they have data
And then go back to the Inventory list for Property tab, those fields do not have data.
Presumably the program is getting mixed up because of the units (?)
Expected Behavior
All the fields in the ESPM report template would be imported into SEED via the new Import Portfolio Manager Data, which allows the user to log into their ESPM account and pick the report to download data from
Actual Behavior
In the test ESPM account I set up, all the fields except Site EUI (kBtu/ft²) & Source EUI (kBtu/ft²) were imported. It could have to do with the units?
Steps to Reproduce
Org: LBNL 20 Cycle: 2017 Calendar Year ESPM Downloaded report is in this issue folder: https://drive.google.com/open?id=1CHJBkUgU3W4uYta0chZowN7suvyjVybp
From the LBNL ESPM test account that I set up, I imported data from the "Data Request:SEED City Test Report April 24 - Test 2" under "SEED City Test Report". The 4 records imported properly into SEED
However, when I compare, field by field, the data imported into SEED vs the data in the file downloaded from ESPM, two fields are missing from the SEED import --
Instance Information
instance: dev1 SHA: 6639ad8