sasrigais commented 4 years ago

Ordernumbers > 1000 are stored as nan, and led to errors, therefore skip them. Only a workaround at the moment, should be fixed in FEMAG. See also #56

When freezing using cxfreeze, sys._MEIPASS is not created, so check for existance.

Short circuit parameters for calculation with 1 beta angle should already be implemented...

Loading a previous bch-file maybe only for special usecase, when reading the airgap flux density after doing a sc-simulation...