Open ryancoe opened 3 years ago
Note that we had originally conceptualized this issues a wave maker tuning activity. We will limit this issue to a first step of characterization and leave tuning to a separate issue.
I'm not 100% sure this is worth tackling. Not only did we observe significant capacitive coupling when touching the probes, but the data looks really noisy inconsistent to me: (position determined by encoder) plotted with: wavemakercharacterize.txt
You may be right @nickross4444. Could you upload a zip of the data for me to look at?
Data used for the previous plots:
Other testing data: Open.loop.data.zip
Most recent and extensive dataset, collected during demo day:
@nickross4444 - These files are empty...?
Sorry about that @ryancoe, they should be correct now.
After completing #3 and #100...
f = [1, 1.5, 2, 2.5, 3, 3.5, 4]
Hz,A = [5, 10, 20, 30, 40]
mm)We will present this work in Section 7 of the HardwareX paper.