blynch commented 8 years ago

After discharging on a battery, the board will not wake up again. I've tried flashing it twice. It will not accept config signal from the on-board switch or is it affected by a reset. This happens with the battery or direct connect via usb to my laptop. The following statements are streaming to the serial console without end:

Fatal exception (0): epc1=0x4020d310, epc2=0x00000000, epc3=0x00000000, excvaddr=0x00000000, depc=0x0 0000000 Fatal exception (0): epc1=0x4020d310, epc2=0x00000000, epc3=0x00000000, excvaddr=0x00000000, depc=0x0 0000000 Fatal exception (0): epc1=0x4020d310, epc2=0x00000000, epc3=0x00000000, excvaddr=0x00000000, depc=0x0 0000000

blynch commented 8 years ago

Additional message printed just after pressing reset:

ets Jan 8 2013,rst cause:2, boot mode:(3,7)

load 0x40100000, len 1396, room 16 tail 4 chksum 0x89 load 0x3ffe8000, len 776, room 4 tail 4 chksum 0xe8 load 0x3ffe8308, len 540, room 4 tail 8 chksum 0xc0 csum 0xc0

2nd boot version : 1.4(b1) SPI Speed : 40MHz SPI Mode : QIO SPI Flash Size & Map: 32Mbit(1024KB+1024KB) jump to run user1 @ 1000

KillingJacky commented 8 years ago

Hi @blynch , seems like corruption is produced during your flashing the firmware. You can try the backdoor I left to turn over the firmware to the fail-safe partition. From the streaming of your serial console, I assume that your Wio unit will reboot itself after a while (caused by the watch dog). If this is right, then you just press and hold down the CONFIG button and wait the Wio unit reboot itself and keep pressing down while it's rebooting. When it reboots abnormally with CONFIG button pressed down at the same time, the firmware will try to roll back to the fail-safe partition.

blynch commented 8 years ago

Hey @KillingJacky, thanks for the response! It doesn't appear to get past the initial boot or restart on its own. Holding down config has no affect along with pressing it repeatedly. Tried flashing it again to no avail. It does not appear to roll back to the fail-safe partition. Is there a debug version of the firmware that could yield more information?

KillingJacky commented 8 years ago

Hi @blynch If it cant pass the initial boot, the debug message from the firmware cant be printed then, as the serial cant be initialized. The messages you see at the serial console is printed by the bootloader, not the Wio firmware( in the flash storage of Wio, there're few partitions: bootloader, firmware-partition-1, firmware-partition-2, parameters-partition...). You said you tried flashing it again, what kind of flashing have you done? with ESP flash tool? If so, which files have you flashed? user1.bin and user2.bin ? or user1.bin, user2.bin and bootloader and a few more files like described in this guide ? I think if the hardware is not damaged, flashing all the partition binaries will fix it, like a factory process.

blynch commented 8 years ago

@KillingJacky I followed the steps in the guide on my mac using the ESP python tool. It included user1.bin, user2.bin, esp_init_data_default.bin, blank.bin and the bootloader. I don't think the hardware is damaged. Do you have an updated bootloader I can test with?

KillingJacky commented 8 years ago

The bootloader in this guide https://github.com/Seeed-Studio/Wio_Link/wiki/Advanced%20User%20Guide#5-repair-bricked-wio-link is the working one. It's not the bootloader caused the case. If you flashed these 5 binaries and still no avail, I will doubt that the SPI flash may be damaged somehow. I have ever encountered such a failed unit which is fixed by the replacement of the SPI flash.

juansezoh commented 7 years ago

Hello, I have the same problem with a WioNode. I already use the erase_flash command and reload the bin files and it still does not work. Is there a command to return to the factory settings ?. The erease_flash erases all partitions ?. I appreciate what you can help me, thank you.

awong1900 commented 7 years ago

@juansezoh Now, no reset command to return to the factory settings. If your wio device is broke, you must update the firmware. That initial firmware of WioLink and WioNoe is the same. Please follow this on Windows, or this on Mac/Linux