Severson-Group / AMDC-Hardware

Circuit board designs for controlling advanced motor systems
http://docs.amdc.dev/hardware
34 stars 3 forks source link

uInverter: Redundant jumper provision to disconnect series R-L load - Simplify design #197

Closed purohitparth25 closed 2 years ago

purohitparth25 commented 2 years ago

Present design of uInverter has two screw connectors on either side of the series R-L load (J2 and J3 in the image), however, to test the current regulation and other algorithms, we need the series R-L load anyways and the user would end up shorting out the jumpers at all times. A design simplification can be made by removing the screw connector between the switch node and R-L load (Connector J2) to simplify the design and provide a test point instead for more flexibility in measurement.

Half-Bridge schematic - uInverter revA:

image