Added 895 GC and YBranch model #256

Closed maevewentland closed 1 year ago

lukasc-ubc commented 1 year ago

YBranch wasn't working; things weren't connected. Fixing.

image
lukasc-ubc commented 1 year ago

What are the oscillations from? Did you account for fabrication process bias at ANT?

image
lukasc-ubc commented 1 year ago
image

looks like the splitters have the same ratio.

lukasc-ubc commented 1 year ago

Problem with the terminator.

image
lukasc-ubc commented 1 year ago

How did you simulate the loss for the Bezier parameters? The loss numbers were much higher than 0.01 dB in the mode calculations.

maevewentland commented 1 year ago

I used the loss_vs_bezier FDTD simulation that was included with the SiEPIC Passives course resources. I'm also not entirely convinced by the results I found. I realized last night that I probably placed the monitors asymmetrically which would affect the loss that was calculated.

JackdeGooyer commented 1 year ago

I could not tell you where the oscillations are from. We think it is from the placement of the mode expansion solver for S-param extraction. They should not have the same ratio, I will look into that, but it may come from the previous concern. I used the Y-branch S-param extractor and modified for four ports.

We did not factor in fabrication bias.