Context

This feature covers the inverter functional profiles

Stakeholders

@ChrisBroenni Alain Stüki Alain Aerni (for Battery)

High Priority

Medium Priority

all that can be tested on Fronius Symo & GEN24

on demand

the many other Sunspec profiles

Request to be reassigned

ergozeller commented 1 year ago

Hi @ChrisBroenni Welche Inverter FP sind jetzt geplant? Im Master Excel sind folgende aufgeführt:

gilt dies noch (insb. mit Deinen aktuellen SunSpec Erkenntnissen)?

ChrisBroenni commented 1 year ago

Due to the large number of Sunspec Subprofiles these enumerations have been changed since a while. I did not yet remove the initial definitions, sorry for the confusion being generated removed ph21: ### SunspInvImmCtrl removed ph22: ### SunspInvOpState removed ph23:### SunspInvModel

High Priority

  1. ph80: SunspCommon001: All Sunspec compliant devices must include this as the first model
  2. ph86: SunspInverter113: Sunspec: model for s3 phase inverter monitoring using float values
  3. ph90: SunspImmControl123: Immediate Inverter Controls
  4. ph98: SunspBatteryBaseModel802: Battery SOC management (only public battery definition available)

Medium Priority all that can be tested on Fronius Symo & GEN24

  1. ph83: SunspInverter103: Sunspec: model for 3 phase inverter monitoring (Int and SF)
  2. ph87: SunspNameplate120: Sunspec: Inverter Controls Nameplate Ratings
  3. ph88: SunspBasicSettings121: Inverter Controls Basic Settings
  4. ph89: SunspMeasurementStatus122: Inverter Controls Extended Measurements and Status
  5. ph91: SunspBasicStorage124: SunspBasicStorage124
  6. ph92: SunspMultMPP160: Model for multiple Maximum Power Point Trackers

Low Priority

  1. ph93: SunspStaticVoltVar126: Static Volt-VAR Arrays for Q = f (U/Uref)
  2. ph94: SunspFreqWattParam127: Parameterized Frequency-Watt compensation
  3. ph95: SunspWattPF131: Parameterized Watt-Power Factor Crv PF = f (P/Pmax)
  4. ph96: SunspVoltWatt132: Parameterized Voltage-Power Factor Crv P = f (U/Uref)
  5. ph97: SunspFreqWattCrv134 Curve-Based Frequency-Watt curve P = f (F/Fref)
  6. ph81: SunspInverter101: Sunspec: model for single phase inverter monitoring (Int and SF)
  7. ph82: SunspInverter102: Sunspec: model for split phase inverter monitoring (Int and SF)
  8. ph84: SunspInverter111: Sunspec: model for single phase inverter monitoring using float values
  9. ph85: SunspInverter112: Sunspec: model for split phase inverter monitoring using float values

on demand the many other Sunspec profiles

must be assigend by ergozeller Not part of Sunspec but meter _PowerFactor not part of Sunspec but SGCP ph62 EEGCurtailment

ergozeller commented 1 year ago

Merci @ChrisBroenni , ich hab die Liste mal so in die Description übernommen und Issues für jedes FP erstellt.

ChrisBroenni commented 1 year ago

es gibt noch Anpassungen im Prozess:

Request to be reassigned to the person according the group alignement