Open Astat opened 1 year ago
I think this is an important bug, because of this I unplugged the door sensor, otherwise the manual calibration process could not be done. That this is possible is also a hardware bug, without connected sensor the printer assumes a closed door...
I have encountered this same error and feel it should be prioritized to be resolved.
Happening when starting a laser job from the control system, "Laser Job Preparation" / "Set Work Origin (2/2)" / "Set XY Origin". It happens that I open the door of the enclosure at that stage, in order to tighten a screw or move a little the work piece for instance.
Everything works perfectly and I can continue onto the job from there once the door is closed, except for one part. The laser shuts down at once when the door opens (as intented, working great) - but it never goes back on once I close back the door, with no option available either to do it manually.
It feels like the laser should turn on again once the door is closed, in order to position the toolhead properly.