StefaE / PVForecast

Forecasts to optimize electricity consumption for rooftop PV (photo-voltaic) installations
GNU General Public License v3.0
50 stars 13 forks source link

two roofs and different # of modules per string #3

Closed astrakid closed 3 years ago

astrakid commented 3 years ago

hi, is it possible to configure my PVSystem with 2 roofs (one east, one west) and 5 strings (3x11, 2x15 modules)? couldn't find how to put it into the config file, help is appreciated.

regards, andre

StefaE commented 3 years ago

not yet - but coming; expect approx. 1 week from now

astrakid commented 3 years ago

what? really cool. as stated, i am not an programmer, but i try to help where i can and understand lots of basics. started with influx2.py as well. just don't have the overview what has to be changed. maybe we can discuss it elsewhere (slack / telegram, / signal / ...)?

StefaE commented 3 years ago

Don't have too many of these toys :-( - you can PM me over at https://www.photovoltaikforum.com/, user Stefan_E, then we'll figure something out ... eMail or so

StefaE commented 3 years ago

Beta version of code for split array configuration released in a branch - pls. let me know if it works. Configuration is described in readme.md

StefaE commented 3 years ago

Branch merged back into trunk, released as v1.01