sofar 8.8ktl-x does not work after updating to 1.5 #394

Open tomkolp opened 10 months ago

tomkolp commented 10 months ago

After updating to 1.5, all entities are unavailable. Downgrade solves the problem.

lukazareba commented 9 months ago

Create sofar_ktl_x_g3.yaml file in /config/config/custom_components/solarman/inverter_definitions folder with content as below

# SOFAR Solar 8.8KTLX-G3

requests:
  - start: 0x0400
    end: 0x042B
    mb_functioncode: 0x03
  - start: 0x0482
    end: 0x04A5
    mb_functioncode: 0x03
  - start: 0x0582
    end: 0x0589
    mb_functioncode: 0x03
  - start: 0x0682
    end: 0x068B
    mb_functioncode: 0x03

parameters:
  - group: Solar
    items:
      - name: 'PV Generation today
        class: 'energy'
        state_class: 'total'
        uom: 'kWh'
        scale: 0.01
        rule: 1
        registers: [0x0685, 0x0684]
        icon: 'mdi:solar-power'

      - name: 'PV Generation total'
        class: 'energy'
        state_class: 'total_increasing'
        uom: 'kWh'
        scale: 0.1
        rule: 3
        registers: [0x0687, 0x0686]
        icon: 'mdi:solar-power'

      - name: 'PV1 Power'
        class: 'power'
        state_class: 'measurement'
        uom: 'W'
        scale: 10
        rule: 1
        registers: [0x0586]
        icon: 'mdi:lightning-bolt'

      - name: 'PV2 Power'
        class: 'power'
        state_class: 'measurement'
        uom: 'W'
        scale: 10
        rule: 1
        registers: [0x0589]
        icon: 'mdi:lightning-bolt'

      - name: 'PV1 Voltage''
        class: 'voltage'
        state_class: 'measurement'
        uom: 'V'
        scale: 0.1
        rule: 1
        registers: [0x0584]
        icon: 'mdi:sine-wave'

      - name: 'PV2 Voltage'
        class: 'voltage'
        state_class: 'measurement'
        uom: 'V'
        scale: 0.1
        rule: 1
        registers: [0x0587]
        icon: 'mdi:sine-wave'

      - name: 'PV1 Current'
        class: 'current'
        state_class: 'measurement'
        uom: 'A'
        scale: 0.01
        rule: 1
        registers: [0x0585]
        icon: 'mdi:current-ac'

      - name: 'PV2 Current'
        class: 'current'
        state_class: 'measurement'
        uom: 'A'
        scale: 0.01
        rule: 1
        registers: [0x0588]
        icon: 'mdi:current-ac'

  - group: Grid
    items:
      - name: 'Grid Frequency'
        class: 'frequency'
        state_class: 'measurement'
        uom: 'Hz'
        scale: 0.01
        rule: 1
        registers: [0x0484]
        icon: 'mdi:home-lightning-bolt'

      - name: 'Active Power Output Total'
        class: 'power'
        state_class: 'measurement'
        uom: 'W'
        scale: 10
        rule: 2
        registers: [0x0485]
        icon: 'mdi:lightning-bolt'

      - name: 'Active Power Output Total kW'
        class: 'power'
        state_class: 'measurement'
        uom: 'kW'
        scale: 0.01
        rule: 2
        registers: [0x0485]
        icon: 'mdi:lightning-bolt'

      - name: 'Voltage Phase R'
        class: 'voltage'
        state_class: 'measurement'
        uom: 'V'
        scale: 0.1
        rule: 2
        registers: [0x048D]
        icon: 'mdi:sine-wave'

      - name:  'Current Phase R'
        class: 'current'
        state_class: 'measurement'
        uom: 'A'
        scale: 0.01
        rule: 2
        registers: [0x048E]
        icon: 'mdi:current-ac'

      - name:  'Voltage Phase S'
        class: 'voltage'
        state_class: 'measurement'
        uom: 'V'
        scale: 0.1
        rule: 2
        registers: [0x0498]
        icon: 'mdi:sine-wave'

      - name:  'Current Phase S'
        class: 'current'
        state_class: 'measurement'
        uom: 'A'
        scale: 0.01
        rule: 2
        registers: [0x0499]
        icon: 'mdi:current-ac'

      - name:  'Voltage Phase T'
        class: 'voltage'
        state_class: 'measurement'
        uom: 'V'
        scale: 0.1
        rule: 2
        registers: [0x04A3]
        icon: 'mdi:sine-wave'

      - name:  'Current Phase T'
        class: 'current'
        state_class: 'measurement'
        uom: 'A'
        scale: 0.01
        rule: 2
        registers: [0x04A4]
        icon: 'mdi:current-ac'

  - group: Inverter
    items:
      - name: 'Inverter status'
        class: ''
        state_class: 'measurement'
        uom: ''
        scale: 1
        rule: 1
        registers: [0x0404]
        lookup:
          - key: 0
            value: 'Stand-by'
          - key: 1
            value: 'Self-checking'
          - key: 2
            value: 'Normal'
          - key: 3
            value: 'FAULT'
          - key: 4
            value: 'Permanent'
        icon: 'mdi:wrench'

      - name: 'Module temperature'
        class: 'temperature'
        uom: '°C'
        scale: 0.1
        rule: 2
        registers: [0x0683]
        icon: 'mdi:thermometer'

      - name: 'Ambient temperature'
        class: 'temperature'
        uom: '°C'
        scale: 1
        rule: 2
        registers: [0x0418]
        icon: 'mdi:thermometer'

      - name: 'Radiator temperature'
        class: 'temperature'
        uom: '°C'
        scale: 1
        rule: 2
        registers: [0x041A]
        icon: 'mdi:thermometer'

      - name: 'Insulation Resistance'
        class: ''
        state_class: 'measurement'
        uom: 'Ω'
        scale: 1
        rule: 1
        registers: [0x042B]
        icon: 'mdi:omega'

      - name: 'Generation time today'
        class: ''
        state_class: 'measurement'
        uom: 'min'
        scale: 1
        rule: 1
        registers: [0x0426]
        icon: 'mdi:clock-time-nine-outline'

      - name: 'Total generation time'
        class: ''
        state_class: 'measurement'
        uom: 'min'
        scale: 1
        rule: 1
        registers: [0x0428, 0x0427]
        icon: 'mdi:clock-time-nine-outline'

      - name: 'Total working time'
        class: ''
        state_class: 'measurement'
        uom: 'min'
        scale: 1
        rule: 1
        registers: [0x042A, 0x0429]
        icon: 'mdi:clock-time-nine-outline'

  - group: Alert
    items:
      - name: 'Alert'
        class: ''
        state_class: ''
        uom: ''
        scale: 1
        rule: 6
        registers:
          [
            0x0405,
            0x0406,
            0x0407,
            0x0408,
            0x0409,
            0x040A,
            0x040B,
            0x040C,
            0x040D,
            0x040E,
            0x040F,
            0x0410,
          ]

      - name: 'Fault 1'
        class: ''
        state_class: ''
        uom: ''
        scale: 1
        rule: 1
        registers: [0x0405]
        isstr: true
        icon: 'mdi:wrench'
        lookup:
          - key: 0
            value: 'No error'
          - key: 1
            value: 'ID01 Grid Over Voltage Protection'
          - key: 2
            value: 'ID02 Grid Under Voltage Protection'
          - key: 4
            value: 'ID03 Grid Over Frequency Protection'
          - key: 8
            value: 'ID04 Grid Under Frequency Protection'
          - key: 16
            value: 'ID05 Leakage current fault'
          - key: 32
            value: 'ID06 High penetration error'
          - key: 64
            value: 'ID07 Low penetration error'
          - key: 128
            value: 'ID08 Islanding error'
          - key: 256
            value: 'ID09 Grid voltage transient value overvoltage 1'
          - key: 512
            value: 'ID10 Grid voltage transient value overvoltage 2'
          - key: 1024
            value: 'ID11 Grid line voltage error'
          - key: 2048
            value: 'ID12 Inverter voltage error'
          - key: 4096
            value: 'ID13 Anti-backflow overload'
          - key: 8192
            value: 'ID14'
          - key: 16384
            value: 'ID15'
          - key: 32768
            value: 'ID16'

      - name: 'Fault 2'
        class: ''
        state_class: ''
        uom: ''
        scale: 1
        rule: 1
        icon: 'mdi:wrench'
        isstr: true
        registers: [0x0406]
        lookup:
          - key: 0
            value: 'No error'
          - key: 1
            value: 'ID17 Grid current sampling error'
          - key: 2
            value: 'ID18 Grid current DC component sampling error (AC side)'
          - key: 4
            value: 'ID19 Grid voltage sampling error (DC side)'
          - key: 8
            value: 'ID20 Grid voltage sampling error (AC side)'
          - key: 16
            value: 'ID21 Leakage current sampling error (DC side)'
          - key: 32
            value: 'ID22 Leakage current sampling error (AC side)'
          - key: 64
            value: 'ID23 Load voltage DC component sampling error'
          - key: 128
            value: 'ID24 DC input current sampling error'
          - key: 256
            value: 'ID25 DC component sampling error of grid current (DC side)'
          - key: 512
            value: 'ID26 DC input branch current sampling error'
          - key: 1024
            value: 'ID27'
          - key: 2048
            value: 'ID28'
          - key: 4096
            value: 'ID29 Leakage current consistency error'
          - key: 8192
            value: 'ID30 Grid voltage consistency error'
          - key: 16384
            value: 'ID31 DCI consistency error'
          - key: 32768
            value: 'ID32'

      - name: 'Fault 3'
        class: ''
        state_class: ''
        uom: ''
        scale: 1
        rule: 1
        icon: 'mdi:wrench'
        isstr: true
        registers: [0x0407]
        lookup:
          - key: 0
            value: 'No error'
          - key: 1
            value: 'ID033 SPI communication error (DC side)'
          - key: 2
            value: 'ID034 SPI communication error (AC side)'
          - key: 4
            value: 'ID035 Chip error (DC side)'
          - key: 8
            value: 'ID036 Chip error (AC side)'
          - key: 16
            value: 'ID037 Auxiliary power error'
          - key: 32
            value: 'ID038 Inverter soft start failure'
          - key: 64
            value: 'ID039 '
          - key: 128
            value: 'ID040 '
          - key: 256
            value: 'ID041 Relay detection failure'
          - key: 512
            value: 'ID042 Low insulation impedance'
          - key: 1024
            value: 'ID043 Grounding error'
          - key: 2048
            value: 'ID044 Input mode setting error'
          - key: 4096
            value: 'ID045 CT error'
          - key: 8192
            value: 'ID046 Input reversal error'
          - key: 16384
            value: 'ID047 Parallel error'
          - key: 32768
            value: 'ID048 Serial number error'

      - name: 'Fault 4'
        class: ''
        state_class: ''
        uom: ''
        scale: 1
        rule: 1
        icon: 'mdi:wrench'
        registers: [0x0408]
        isstr: true
        lookup:
          - key: 0
            value: 'No error'
          - key: 1
            value: 'ID049 Battery temperature protection'
          - key: 2
            value: 'ID050 Heat sink 1 temperature protection'
          - key: 4
            value: 'ID051 Heater 2 temperature protection'
          - key: 8
            value: 'ID052 Heater 3 temperature protection'
          - key: 16
            value: 'ID053 Heatsink 4 temperature protection'
          - key: 32
            value: 'ID054 Heatsink 5 temperature protection'
          - key: 64
            value: 'ID055 Radiator 6 temperature protection'
          - key: 128
            value: 'ID056 '
          - key: 256
            value: 'ID057 Ambient temperature 1 protection'
          - key: 512
            value: 'ID058 Ambient temperature 2 protection'
          - key: 1024
            value: 'ID059 Module 1 temperature protection'
          - key: 2048
            value: 'ID060 Module 2 temperature protection'
          - key: 4096
            value: 'ID061 Module 3 temperature protection'
          - key: 8192
            value: 'ID062 Module temperature difference is too large'
          - key: 16384
            value: 'ID063 '
          - key: 32768
            value: 'ID064 '

      - name: 'Fault 5'
        class: ''
        state_class: ''
        uom: ''
        scale: 1
        rule: 1
        icon: 'mdi:wrench'
        registers: [0x0409]
        isstr: true
        lookup:
          - key: 0
            value: 'No error'
          - key: 1
            value: 'ID065 Bus voltage RMS unbalance'
          - key: 2
            value: 'ID066 Bus voltage transient   value unbalance'
          - key: 4
            value: 'ID067 Undervoltage of busbar during grid connection'
          - key: 8
            value: 'ID068 Bus bar low voltage'
          - key: 16
            value: 'ID069 PV overvoltage'
          - key: 32
            value: 'ID070 Battery over-voltage'
          - key: 64
            value: 'ID071 LLCBus overvoltage protection'
          - key: 128
            value: 'ID072 Inverter bus voltage RMS software overvoltage'
          - key: 256
            value: 'ID073 Inverter bus voltage transient value software overvoltage'
          - key: 512
            value: 'ID074 Flying Cross Capacitor Overvoltage Protection'
          - key: 1024
            value: 'ID075 Flying Cross capacitor undervoltage protection'
          - key: 2048
            value: 'ID076 '
          - key: 4096
            value: 'ID077 '
          - key: 8192
            value: 'ID078 '
          - key: 16384
            value: 'ID079 '
          - key: 32768
            value: 'ID080 '

      - name: 'Fault 6'
        class: ''
        state_class: ''
        uom: ''
        scale: 1
        rule: 1
        icon: 'mdi:wrench'
        isstr: true
        registers: [0x040A]
        lookup:
          - key: 0
            value: 'No error'
          - key: 1
            value: 'ID081 Battery overcurrent software protection'
          - key: 2
            value: 'ID082 Dci overcurrent protection'
          - key: 4
            value: 'ID083 Output transient current protection'
          - key: 8
            value: 'ID084 BuckBoost software overcurrent'
          - key: 16
            value: 'ID085 Output RMS current protection'
          - key: 32
            value: 'ID086 PV instantaneous current overcurrent software protection'
          - key: 64
            value: 'ID087 PV parallel uneven current'
          - key: 128
            value: 'ID088 Output current unbalance'
          - key: 256
            value: 'ID089 PV software overcurrent protection'
          - key: 512
            value: 'ID090 Balanced circuit overcurrent protection'
          - key: 1024
            value: 'ID091 Resonance protection'
          - key: 2048
            value: 'ID092 '
          - key: 4096
            value: 'ID093 '
          - key: 8192
            value: 'ID094 '
          - key: 16384
            value: 'ID095 '
          - key: 32768
            value: 'ID096 '

      - name: 'Fault 7'
        class: ''
        state_class: ''
        uom: ''
        scale: 1
        rule: 1
        icon: 'mdi:wrench'
        isstr: true
        registers: [0x040B]
        lookup:
          - key: 0
            value: 'No error'
          - key: 1
            value: 'ID097 LLC bus hardware overvoltage'
          - key: 2
            value: 'ID098 Inverter bus hardware overvoltage'
          - key: 4
            value: 'ID099 BuckBoost hardware overcurrent'
          - key: 8
            value: 'ID100 Battery hardware overcurrent'
          - key: 16
            value: 'ID101 '
          - key: 32
            value: 'ID102 PV hardware overcurrent'
          - key: 64
            value: 'ID103 AC output hardware overcurrent'
          - key: 128
            value: 'ID104 '
          - key: 256
            value: 'ID105 Power meter error'
          - key: 512
            value: 'ID106 Serial number model error'
          - key: 1024
            value: 'ID107 '
          - key: 2048
            value: 'ID108 '
          - key: 4096
            value: 'ID109 '
          - key: 8192
            value: 'ID110 Overload protection 1'
          - key: 16384
            value: 'ID111 Overload protection 2'
          - key: 32768
            value: 'ID112 Overload protection 3'

      - name: 'Fault 8'
        class: ''
        state_class: ''
        uom: ''
        scale: 1
        rule: 1
        icon: 'mdi:wrench'
        registers: [0x040C]
        isstr: true
        lookup:
          - key: 0
            value: 'No error'
          - key: 1
            value: 'ID113 Overtemperature derating'
          - key: 2
            value: 'ID114 Frequency down load'
          - key: 4
            value: 'ID115 Frequency loading'
          - key: 8
            value: 'ID116 Voltage down load'
          - key: 16
            value: 'ID117 Voltage loading'
          - key: 32
            value: 'ID118 '
          - key: 64
            value: 'ID119 '
          - key: 128
            value: 'ID120 '
          - key: 256
            value: 'ID121 Lightning protection failure (DC)'
          - key: 512
            value: 'ID122 Lightning protection failure (AC)'
          - key: 1024
            value: 'ID123 '
          - key: 2048
            value: 'ID124 Battery low voltage protection'
          - key: 4096
            value: 'ID125 Battery low voltage shutdown'
          - key: 8192
            value: 'ID126 Battery low voltage pre-alarm'
          - key: 16384
            value: 'ID127 '
          - key: 32768
            value: 'ID128 '

      - name: 'Fault 9'
        class: ''
        state_class: ''
        uom: ''
        scale: 1
        rule: 1
        icon: 'mdi:wrench'
        isstr: true
        registers: [0x040D]
        lookup:
          - key: 0
            value: 'No error'
          - key: 1
            value: 'ID129 Output hardware overcurrent permanent fault'
          - key: 2
            value: 'ID130 Bus overvoltage permanent fault'
          - key: 4
            value: 'ID131 Bus hardware over-voltage permanent fault'
          - key: 8
            value: 'ID132 PV uneven flow permanent fault'
          - key: 16
            value: 'ID133 Battery overcurrent permanent fault in EPS mode'
          - key: 32
            value: 'ID134 Output transient overcurrent permanent fault'
          - key: 64
            value: 'ID135 Output current unbalance permanent fault'
          - key: 128
            value: 'ID136 '
          - key: 256
            value: 'ID137 Input mode setting error permanent fault'
          - key: 512
            value: 'ID138 Input overcurrent permanent fault'
          - key: 1024
            value: 'ID139 Input hardware overcurrent permanent fault'
          - key: 2048
            value: 'ID140 Relay permanent fault'
          - key: 4096
            value: 'ID141 Bus unbalance permanent fault'
          - key: 8192
            value: 'ID142 Lightning protection permanent fault - DC side'
          - key: 16384
            value: 'ID143 Lightning protection permanent fault - AC side'
          - key: 32768
            value: 'ID144 '

      - name: 'Fault 10'
        class: ''
        state_class: ''
        uom: ''
        scale: 1
        rule: 1
        icon: 'mdi:wrench'
        isstr: true
        registers: [0x040E]
        lookup:
          - key: 0
            value: 'No error'
          - key: 1
            value: 'ID145 USB fault'
          - key: 2
            value: 'ID146 WIFI fault'
          - key: 4
            value: 'ID147 Bluetooth fault'
          - key: 8
            value: 'ID148 RTC clock fault'
          - key: 16
            value: 'ID149 Communication board EEPROM error'
          - key: 32
            value: 'ID150 Communication board FLASH error'
          - key: 64
            value: 'ID151 '
          - key: 128
            value: 'ID152 Safety regulation version error'
          - key: 256
            value: 'ID153 SCI communication error (DC side)'
          - key: 512
            value: 'ID154 SCI communication error (AC side)'
          - key: 1024
            value: 'ID155 SCI communication error (convergence board side)'
          - key: 2048
            value: 'ID156 Software version inconsistency'
          - key: 4096
            value: 'ID157 Lithium battery 1 communication error'
          - key: 8192
            value: 'ID158 Li-ion battery 2 communication error'
          - key: 16384
            value: 'ID159 Lithium battery 3 communication error'
          - key: 32768
            value: 'ID160 Lithium battery 4 communication failure'

      - name: 'Fault 11'
        class: ''
        state_class: ''
        uom: ''
        scale: 1
        rule: 1
        icon: 'mdi:wrench'
        registers: [0x040F]
        isstr: true
        lookup:
          - key: 0
            value: 'No error'
          - key: 1
            value: 'ID161 Forced shutdown'
          - key: 2
            value: 'ID162 Remote shutdown'
          - key: 4
            value: 'ID163 Drms0 shutdown'
          - key: 8
            value: 'ID164 '
          - key: 16
            value: 'ID165 Remote down load'
          - key: 32
            value: 'ID166 Logic interface down load'
          - key: 64
            value: 'ID167 Anti-Reverse Flow Downgrade'
          - key: 128
            value: 'ID168 '
          - key: 256
            value: 'ID169 Fan 1 failure'
          - key: 512
            value: 'ID170 Fan 2 failure'
          - key: 1024
            value: 'ID171 Fan 3 failure'
          - key: 2048
            value: 'ID172 Fan 4 failure'
          - key: 4096
            value: 'ID173 Fan 5 failure'
          - key: 8192
            value: 'ID174 Fan 6 failure'
          - key: 16384
            value: 'ID175 Fan 7 fault'
          - key: 32768
            value: 'ID176 Meter communication failure'

      - name: 'Fault 12'
        class: ''
        state_class: ''
        uom: ''
        scale: 1
        rule: 1
        icon: 'mdi:wrench'
        registers: [0x0410]
        isstr: true
        lookup:
          - key: 0
            value: 'No error'
          - key: 1
            value: 'ID177 BMS over-voltage alarm'
          - key: 2
            value: 'ID178 BMS undervoltage alarm'
          - key: 4
            value: 'ID179 BMS high temperature alarm'
          - key: 8
            value: 'ID180 BMS low temperature alarm'
          - key: 16
            value: 'ID181 BMS charge/discharge overload alarm'
          - key: 32
            value: 'ID182 BMS short circuit alarm'
          - key: 64
            value: 'ID183 BMS version inconsistency'
          - key: 128
            value: 'ID184 BMS CAN version inconsistency'
          - key: 256
            value: 'ID185 BMS CAN version is too low'
          - key: 512
            value: 'ID186 '
          - key: 1024
            value: 'ID187 '
          - key: 2048
            value: 'ID188 '
          - key: 4096
            value: 'ID189 Arc device communication failure'
          - key: 8192
            value: 'ID190 DC arc alarm fault'
          - key: 16384
            value: 'ID191 PID repair failed'
          - key: 32768
            value: 'ID192 PLC module heartbeat loss'
lukazareba commented 9 months ago

Also add an entry ( 'sofar_ktl_x_g3.yaml', ) in the const.py file

from datetime import timedelta

DOMAIN = 'solarman'

DEFAULT_PORT_INVERTER = 8899
DEFAULT_INVERTER_MB_SLAVEID = 1
DEFAULT_LOOKUP_FILE = 'deye_hybrid.yaml'
LOOKUP_FILES = [
    'deye_2mppt.yaml',
    'deye_4mppt.yaml',
    'deye_hybrid.yaml',
    'deye_sg04lp3.yaml',
    'deye_string.yaml',
    'kstar_hybrid.yaml',
    'sofar_g3hyd.yaml',
    'sofar_hyd3k-6k-es.yaml',
    'sofar_ktl_x_g3.yaml',
    'sofar_lsw3.yaml',
    'sofar_wifikit.yaml',
    'solis_1p8k-5g.yaml',
    'solis_3p-4g.yaml',
    'solis_hybrid.yaml',
    'solis_s6-gr1p.yaml',
    'zcs_azzurro-ktl-v3.yaml',
    'custom_parameters.yaml'
]

MIN_TIME_BETWEEN_UPDATES = timedelta(seconds=15)

CONF_INVERTER_HOST = 'inverter_host'
CONF_INVERTER_PORT = 'inverter_port'
CONF_INVERTER_SERIAL = 'inverter_serial'
CONF_INVERTER_MB_SLAVEID = 'inverter_mb_slaveid'
CONF_LOOKUP_FILE = 'lookup_file'

SENSOR_PREFIX = 'Solarman'
rimelis commented 9 months ago

Version 1.5.0 has a breaking change - the modbus protocol implementation using pysolarmanv5 module instead of internal one existing in previous versions.

lukazareba commented 9 months ago

I don't understand, in general it means it won't work on some inverters now?

rimelis commented 9 months ago

Yes, It may not work at all or work partially. In my case the stick (LSW3_15_270A_1.50) is buggy and pysolarmanv5 is working somehow but keep crashing threads of Home Assistant and generates a lot of mess into log. I decided to revert to older "local implementation" found in version < 1.5.0

NemesisXB commented 7 months ago

@jmccrohan, Any idea?