Open markodraca opened 8 months ago
Super, dass wäre nett wenn du das hier einstellen würdest. Great, it would be nice if you would post it here
Sure
HA power flow card configuration
- type: custom:sunsynk-power-flow-card
cardstyle: full
panel_mode: true
show_solar: true
inverter:
modern: true
autarky: power
three_phase: true
battery:
energy: 16000
shutdown_soc: 5
show_daily: true
invert_power: false
max_power: 12000
full_capacity: 95
empty_capacity: 10
colour: limegreen
solar:
show_daily: true
mppts: 2
max_power: 8700
pv1_name: Istok
pv2_name: Zapad
load:
show_daily: true
max_power: 12000
grid:
show_daily_buy: true
show_daily_sell: true
show_nonessential: true
nonessential_name: Sanitarna
nonessential_icon: mdi:water-boiler
max_power: 6000
entities:
use_timer_248: 'no'
priority_load_243: 'no'
day_battery_charge_70: sensor.solarman_daily_battery_charge
day_battery_discharge_71: sensor.solarman_daily_battery_discharge
day_load_energy_84: sensor.solarman_daily_load_consumption
day_grid_import_76: sensor.solarman_daily_energy_bought
day_grid_export_77: sensor.solarman_daily_energy_sold
day_pv_energy_108: sensor.solarman_daily_production
pv1_power_186: sensor.solarman_pv1_power
pv2_power_187: sensor.solarman_pv2_power
battery_voltage_183: sensor.solarman_battery_voltage
battery_soc_184: sensor.solarman_battery_soc
battery_power_190: sensor.solarman_battery_power
battery_current_191: sensor.solarman_battery_current
pv1_voltage_109: sensor.solarman_pv1_voltage
pv1_current_110: sensor.solarman_pv1_current
pv2_voltage_111: sensor.solarman_pv2_voltage
pv2_current_112: sensor.solarman_pv2_current
inverter_status_59: sensor.solarman_alert
remaining_solar: sensor.energy_production_today_remaining
dc_transformer_temp_90: sensor.solarman_dc_temperature
radiator_temp_91: sensor.solarman_ac_temperature
load_frequency_192: sensor.solarman_grid_frequency
inverter_voltage_154: sensor.solarman_grid_voltage_l1
inverter_voltage_L2: sensor.solarman_grid_voltage_l2
inverter_voltage_L3: sensor.solarman_grid_voltage_l3
inverter_current_164: sensor.solarman_current_l1
inverter_current_L2: sensor.solarman_current_l2
inverter_current_L3: sensor.solarman_current_l3
load_power_L1: sensor.solarman_load_l1_power
load_power_L2: sensor.solarman_load_l2_power
load_power_L3: sensor.solarman_load_l3_power
grid_ct_power_L2: sensor.solarman_external_ct_l2_power
grid_ct_power_L3: sensor.solarman_external_ct_l3_power
essential_power: sensor.solarman_essential_total_load_power
inverter_power_175: sensor.solarman_total_load_power
grid_power_169: sensor.solarman_internal_ct_total_power
grid_ct_power_172: sensor.solarman_external_ct_total_power
nonessential_power: none
Hi
I've edited deye_sg04lp3.yaml so its compatible with https://github.com/slipx06/sunsynk-power-flow-card Basically, just added some registers. If anyone is interested, I can push the script.