Group Address Auto Fill not working with ETS3 CSV File Import #36

Closed svenflender closed 4 years ago

svenflender commented 4 years ago

Hi,

for me the Autofill of Group Address is not working. DPT detection is working and the import has be done. Any Idea?

Best Regards Sven

Supergiovane commented 4 years ago

Hi Sven Have you deployed using Full Deploy button in Node Red?

If unsuccesfull, please paste here your ets csv file, i’ll try directly with that.

svenflender commented 4 years ago

Hi,

yes i have done a full deploy.

It is not the Full Code and i changed the group addresses due to Security ;)

Haus - Jalousien.KG - Jalousien.5/0/1 KG - Jalousie Kino - AUF/AB EIS 1 'Switching' (1 Bit) Low 5/4/50 Haus - Jalousien.KG - Jalousien.5/0/2 KG - Jalousie Kino - STOP EIS 1 'Switching' (1 Bit) Low 5/4/51 Haus - Jalousien.KG - Jalousien.5/0/3 KG - Jalousie Kino - AUF/AB M Uncertain (1 Byte) Low

i am using ETS3.

Supergiovane commented 4 years ago

There are some issues in your file. Look at the “ instead of ‘

Please try with mine here, then watch the video on how to export the ets file. The video is in the homepage of github knx ultimate.

"Group name" "Address" "Central" "Unfiltered" "Description" "DatapointType" "Security" "Attuatori luci" "0/-/-" "" "" "Attuatori luci" "" "Auto" "Luci primo piano" "0/0/-" "" "" "Luci primo piano" "" "Auto" "Camera da letto luce" "0/0/1" "" "" "Camera da letto luce" "DPST-1-8" "Auto" "Loggia camera da letto" "0/0/2" "" "" "Loggia camera da letto" "DPST-1-1" "Auto" "Camera armadi luce" "0/0/3" "" "" "Camera armadi luce" "DPST-1-1" "Auto" "Bagno grande luce" "0/0/4" "" "" "Bagno grande luce" "DPST-1-1" "Auto" "Loggia bagno grande" "0/0/5" "" "" "Loggia bagno grande" "DPST-1-1" "Auto" "Bagno grande specchio (switch)" "0/0/6" "" "" "Bagno grande specchio switch" "DPST-1-1" "Auto" "Lavanderia luce" "0/0/7" "" "" "Lavanderia luce" "DPST-1-1" "Auto" "Lavanderia specchio (switch)" "0/0/8" "" "" "Lavanderia specchio switch" "DPST-1-1" "Auto" "Studio luce" "0/0/9" "" "" "Studio luce" "DPST-1-1" "Auto" "Soggiorno luce (switch)" "0/0/10" "" "" "Soggiorno luce switch" "DPST-1-1" "Auto" "Soggiorno aplique (switch)" "0/0/11" "" "" "Soggiorno aplique switch" "DPST-1-1" "Auto" "Loggia soggiorno cucina" "0/0/12" "" "" "Loggia soggiorno-cucina" "DPST-1-1" "Auto" "Cucina luce" "0/0/13" "" "" "Cucina luce" "DPT-1" "Auto" "Cucina luce pensili" "0/0/14" "" "" "Cucina luce pensili" "DPT-1" "Auto" "Corridoio luce" "0/0/15" "" "" "Corridoio luce" "DPST-1-1" "Auto" "Scala LED" "0/0/16" "" "" "Scala LED" "DPST-1-1" "Auto" "Soggiorno aplique brighness value" "0/0/17" "" "" "" "DPST-5-1" "Auto" "Bagno grande specchio (dim)" "0/0/18" "" "" "Bagno grande specchio dim" "DPST-3-7" "Auto" "Soggiorno luce brighness value" "0/0/19" "" "" "" "DPST-5-1" "Auto" "Lavanderia specchio (dim)" "0/0/20" "" "" "Lavanderia specchio dim" "DPST-3-7" "Auto" "Scala LED cambiacolori RGB" "0/0/21" "" "" "" "DPST-1-1" "Auto" "Bagno grande specchio brightness value" "0/0/22" "" "" "" "DPST-5-1" "Auto" "Soggiorno luce (dim)" "0/0/23" "" "" "Soggiorno luce dim" "DPST-3-7" "Auto"

svenflender commented 4 years ago

In the ETS3 you have only these Options for a CSV Export

image

svenflender commented 4 years ago

I have found the way i can export the 1/1 csv in the ETS3 But it is still not working.

That is how the export look like from the ETS3.

"Group name" "Address" Haus - Jalousien 5/-/- KG - Jalousien 5/0/- KG - Jalousie WC - AUF/AB 5/0/1 KG - Jalousie WC - STOP 5/0/2 KG - Jalousie WC - AUF/AB M 5/0/3

Is there any possibility to integrate an OPC Import. I think that Format is more reliable over the different Versions

Supergiovane commented 4 years ago

So that’s definately incompatible with ETS3. There is no “” in the device name and there’s no datapoint.

Tomorrow i’ll check OPC.

svenflender commented 4 years ago

I have updated to ETS5 and now i have some homework to do. I have to specify all the DTP in the GA.

I will close this Issue.

Supergiovane commented 4 years ago

Good! You’ll never regret! Yes DpT are mandatory and you’ll enjoy how well your visualization and control devices performs, with right dpt!