Support for Shelly Mini PM Gen 3 #15

Closed SY-KALINKA closed 9 months ago

SY-KALINKA commented 9 months ago

Hi, Would it be possible to add support for a generation 3 shelly Mini PM ? I can see that the mini PM should be included but it does not connect My shelly sends data to http://192.168.4.16/rpc/Shelly.GetStatus, but not sure how to change it in the script Thanks

Telekatz commented 9 months ago

Please send the output of http://192.168.4.16/Shelly and http://192.168.4.16/rpc/Shelly.GetStatus.

SY-KALINKA commented 9 months ago

This is output from http://192.168.4.16/shelly

  |   -- | -- name | "shelly" id | "shellypmminig3-ecda3bc32f34" mac | "ECDA3BC32F34" slot | 0 model | "S3PM-001PCEU16" gen | 3 fw_id | "20231219-133933/1.1.0-g34b5d4f" ver | "1.1.0" app | "MiniPMG3" auth_en | false auth_domain | null

and this is http://192.168.4.16/rpc/shelly.GetStatus

  |   -- | -- ble | {} cloud |   connected | true mqtt |   connected | true pm1:0 |   id | 0 voltage | 231.4 current | 0.277 apower | 55.2 freq | 50 aenergy |   total | 478.86 by_minute |   0 | 429.089 1 | 643.634 2 | 858.178 minute_ts | 1706883331 ret_aenergy |   total | 0 by_minute |   0 | 0 1 | 0 2 | 0 minute_ts | 1706883331 sys |   mac | "ECDA3BC32F34" restart_required | false time | "15:15" unixtime | 1706883333 uptime | 27466 ram_size | 261500 ram_free | 151976 fs_size | 1048576 fs_free | 708608 cfg_rev | 20 kvs_rev | 6 schedule_rev | 0 webhook_rev | 0 available_updates | {} reset_reason | 1 wifi |   sta_ip | "192.168.4.16" status | "got ip" ssid | "Kalinka Wifi" rssi | -62 ws |   connected | false
SY-KALINKA commented 9 months ago

Hi,

Thanks for assistance I uploaded the screen shots to github

Best regards Klaus

Sendt fra Outlook til Androidhttps://aka.ms/AAb9ysg


From: Telekatz @.> Sent: Friday, February 2, 2024 2:55:08 PM To: Telekatz/venus.dbus-shellyPlug @.> Cc: SY-KALINKA @.>; Author @.> Subject: Re: [Telekatz/venus.dbus-shellyPlug] Support for Shelly Mini PM Gen 3 (Issue #15)

Please send the output of http://192.168.4.16/Shelly and http://192.168.4.16/rpc/Shelly.GetStatus.

— Reply to this email directly, view it on GitHubhttps://github.com/Telekatz/venus.dbus-shellyPlug/issues/15#issuecomment-1923869507, or unsubscribehttps://github.com/notifications/unsubscribe-auth/AYEH75ZBZCZHIN3QG7H3QQLYRTV3ZAVCNFSM6AAAAABCWL3WJCVHI2DSMVQWIX3LMV43OSLTON2WKQ3PNVWWK3TUHMYTSMRTHA3DSNJQG4. You are receiving this because you authored the thread.Message ID: @.***>

Telekatz commented 9 months ago

Can you try the current version?

SY-KALINKA commented 9 months ago
Hi, Thank you so much, now I got it on my device list as an AC meter however it does not appear on the graphic display ThanksKlaus Sendt fra Mail til Windows Fra: TelekatzSendt: 3. februar 2024 15:00Til: Telekatz/venus.dbus-shellyPlugCc: SY-KALINKA; AuthorEmne: Re: [Telekatz/venus.dbus-shellyPlug] Support for Shelly Mini PM Gen 3 (Issue #15)  Can you try the current version? —Reply to this email directly, view it on GitHub, or unsubscribe.You are receiving this because you authored the thread.Message ID: ***@***.***> [ { ***@***.***": "http://schema.org", ***@***.***": "EmailMessage", "potentialAction": { ***@***.***": "ViewAction", "target": "https://github.com/Telekatz/venus.dbus-shellyPlug/issues/15#issuecomment-1925329231", "url": "https://github.com/Telekatz/venus.dbus-shellyPlug/issues/15#issuecomment-1925329231", "name": "View Issue" }, "description": "View this Issue on GitHub", "publisher": { ***@***.***": "Organization", "name": "GitHub", "url": "https://github.com" } } ]
SY-KALINKA commented 9 months ago

Hi Again,

Its all good now, showing up on the display mimic

Thanks for the assistance

Best regards Klaus

Sendt fra Outlook til Androidhttps://aka.ms/AAb9ysg


From: Telekatz @.> Sent: Saturday, February 3, 2024 3:00:19 PM To: Telekatz/venus.dbus-shellyPlug @.> Cc: SY-KALINKA @.>; Author @.> Subject: Re: [Telekatz/venus.dbus-shellyPlug] Support for Shelly Mini PM Gen 3 (Issue #15)

Can you try the current version?

— Reply to this email directly, view it on GitHubhttps://github.com/Telekatz/venus.dbus-shellyPlug/issues/15#issuecomment-1925329231, or unsubscribehttps://github.com/notifications/unsubscribe-auth/AYEH75Z4SNYLUNW5LWDEVPDYRY7HHAVCNFSM6AAAAABCWL3WJCVHI2DSMVQWIX3LMV43OSLTON2WKQ3PNVWWK3TUHMYTSMRVGMZDSMRTGE. You are receiving this because you authored the thread.Message ID: @.***>

SY-KALINKA commented 9 months ago

Hi again,

Sorry I was too fast.... It was my inverter that was showing AC Loads.... The shelly device does not show anything on the mimic

Do you have any suggestions?

Best regards Klaus

Sendt fra Outlook til Androidhttps://aka.ms/AAb9ysg


From: Telekatz @.> Sent: Saturday, February 3, 2024 3:00:19 PM To: Telekatz/venus.dbus-shellyPlug @.> Cc: SY-KALINKA @.>; Author @.> Subject: Re: [Telekatz/venus.dbus-shellyPlug] Support for Shelly Mini PM Gen 3 (Issue #15)

Can you try the current version?

— Reply to this email directly, view it on GitHubhttps://github.com/Telekatz/venus.dbus-shellyPlug/issues/15#issuecomment-1925329231, or unsubscribehttps://github.com/notifications/unsubscribe-auth/AYEH75Z4SNYLUNW5LWDEVPDYRY7HHAVCNFSM6AAAAABCWL3WJCVHI2DSMVQWIX3LMV43OSLTON2WKQ3PNVWWK3TUHMYTSMRVGMZDSMRTGE. You are receiving this because you authored the thread.Message ID: @.***>

Telekatz commented 9 months ago

What is the role of your Shelly device?

SY-KALINKA commented 9 months ago

Hi,

I changed it from AC Load to Grid Meter and now it shows as AC load ?

Iam just playing now, but want to have a few for my large AC loads.... Like waterheater & heater in the boat.

Have not tested what happens when start the inverter

Best regards Klaus

Sendt fra Outlook til Androidhttps://aka.ms/AAb9ysg


From: Telekatz @.> Sent: Monday, February 5, 2024 5:50:11 PM To: Telekatz/venus.dbus-shellyPlug @.> Cc: SY-KALINKA @.>; Author @.> Subject: Re: [Telekatz/venus.dbus-shellyPlug] Support for Shelly Mini PM Gen 3 (Issue #15)

What is the role of your Shelly device?

— Reply to this email directly, view it on GitHubhttps://github.com/Telekatz/venus.dbus-shellyPlug/issues/15#issuecomment-1927455363, or unsubscribehttps://github.com/notifications/unsubscribe-auth/AYEH75Y75JQCPIHQ5CXQAETYSEEUHAVCNFSM6AAAAABCWL3WJCVHI2DSMVQWIX3LMV43OSLTON2WKQ3PNVWWK3TUHMYTSMRXGQ2TKMZWGM. You are receiving this because you authored the thread.Message ID: @.***>

Telekatz commented 9 months ago

AC loads are only displayed in the device list, not in the graphical display.