Open kareefardi opened 1 week ago
Is the expectation that the isolation cell and the inverter should both be outside the domain being isolated? I want to confirm as that's what makes sense to me.
Is the expectation that the isolation cell and the inverter should both be outside the domain being isolated? I want to confirm as that's what makes sense to me.
To me what makes sense is that they both should be together based on the value of -location
Describe the bug
when using isolation with
-location self
and-clamp_value 1
an inverter is inserted such that the clamped value is inverted:however the inserted inverter is not in the same group and region as the isolation cell:
Expected Behavior
I believe both should belong to the same region/group
Environment
To Reproduce
test-case.tar.gz
Relevant log output
No response
Screenshots
No response
Additional Context