Closed GoogleCodeExporter closed 9 years ago
Im glad that my first bugs that i noticed are here! You are faast Erezra! :)
rcgroups nick: ganapati08
Original comment by happygan...@gmail.com
on 11 Nov 2010 at 9:40
Now have the option to skip test.
Original comment by erezra...@gmail.com
on 12 Nov 2010 at 7:45
Issue 175 has been merged into this issue.
Original comment by erezra...@gmail.com
on 17 Nov 2010 at 3:10
Original comment by erezra...@gmail.com
on 28 Nov 2010 at 10:23
I just flashed the new firmware with the "fixed switch error" with the FrSky
transmitter.
But the switch error still exists. Thou now I can go on by pressing a key.
So still not fixed
Original comment by medifra...@gmail.com
on 28 Nov 2010 at 11:30
Original comment by erezra...@gmail.com
on 29 Nov 2010 at 5:24
Got it now.
Original comment by erezra...@gmail.com
on 2 Dec 2010 at 8:00
Hi !!!
First, congratulation for your work... i'm appreciative...
I'm novice in this project...
So my question maybe has been already posed...
But I try at least !!! ;)
My config is : Turnigy 9x, BackLight, FrSky module, LiPo Batt...
And I flash my Tx with eePe and an AVR Card from SparkFun Electronics...
I use the Flash FrSky (but I've tried other version)... and it has appeared the
mentions "AIL" and "THR" on level 1
I've tested with a Voltmeter the levels on the TX mainboard...
I've noted that the pins "SCK" and "RST" remained at 5V !!!
So it's normal that AIL and THR are ON...
Could you do something ?
Do you know the reason why SCK and RST remain at 5V ?
Have you a solution ?
Thanks for your answers
Thanks for all
Original comment by guillaum...@gmail.com
on 27 Aug 2011 at 6:46
If you flashed the Frsky version of the er9x firmware without making the
hardware modification on your tx, then you will get that switch error... In
that case try to flash the normal er9x version. I think that is your problem..
Original comment by joaoalve...@googlemail.com
on 28 Aug 2011 at 12:40
Hi!
Thanks for this answer...
I 've tryed to flash with the latest er9x...
And ... It 's OK !!! All is good !!!
But I must test the tx/rx connexion...
Original comment by guillaum...@gmail.com
on 31 Aug 2011 at 3:38
Original issue reported on code.google.com by
erezra...@gmail.com