Closed KrishnaIyer closed 5 years ago
Proposed change (Copied from Slack):
- initializing uart at boot
- keep lora power off
- deinitialize uart
- wait
- lora power on
- initialize uart (modifié) The deinitializing of the UART is needed to now power the LoRa module via the UART RX/TX lines