ThomasHoussin / com.thomashoussin.fronius

Adds support for Fronius inverter in Homey
GNU General Public License v3.0
0 stars 0 forks source link

Fronius Symo Gen24 hybrid inverter with BYD batteries not recognized #31

Closed JohPePe closed 2 years ago

JohPePe commented 2 years ago

Hi!

I’ve got a solar farm consisting of two Symo 8 kW inverters, and as of today one Symo Gen24 hybrid with 33 kWh BYD batteries. And a smart meter, 3-phase, connected to the Gen24 inverter. The app only recognizes the two Symo non hybrid inverters, nothing else.

I guess that’s because the app is talking to the datamanager at one of the non hybrid inverters. A connection to solar.web would hopefully solve my problem. What do you think, is it possible?

JohPePe commented 2 years ago

Tried again to get my Gen24 hybrid inverter and BYD battery packs added to the app. Managed to get my two battery-packs added, but they both got status unknown and battery charge 0%. Can it be fixed?

ThomasHoussin commented 2 years ago

Hi. I can have a look. If you have a smartmeter you should get some datas.

Could you post the result of :

JohPePe commented 2 years ago

Hi Thomas!

I found the problem! 😀 Mr smartypants hadn’t enabled the api setting in the Gen24 😂 It’s working just fine now. Thanks for your swift support!

/Johan

27 apr. 2022 kl. 11:18 skrev Thomas Houssin @.***>:

 Hi. I can have a look. If you have a smartmeter you should get some datas.

Could you post the result of :

http:///solar_api/v1/GetInverterRealtimeData.cgi?Scope=System http:///solar_api/v1/GetStorageRealtimeData.cgi?Scope=System http:///solar_api/v1/GetMeterRealtimeData.cgi.cgi?Scope=System — Reply to this email directly, view it on GitHub, or unsubscribe. You are receiving this because you authored the thread.