Wrong loadvalue #60

Open AKjork opened 1 month ago

AKjork commented 1 month ago

The unit powerflow does not show the right value. Somtimes negative values sometimes positve. And the value in Homey does not match the value that shows in solarweb. the load in the house, the blue icon in solar web is the right load.

ThomasHoussin commented 1 month ago

Could you please post in this issue the result of http:///solar_api/v1/GetMeterRealtimeData.cgi?Scope=System and the values that you see in Homey and in solarweb ? Thanks

AKjork commented 1 month ago

Im not sure how to do that Skickat från min iPhone13 okt. 2024 kl. 17:47 skrev Thomas Houssin @.***>: Could you please post in this issue the result of http:///solar_api/v1/GetMeterRealtimeData.cgi?Scope=System and the values that you see in Homey and in solarweb ? Thanks

—Reply to this email directly, view it on GitHub, or unsubscribe.You are receiving this because you authored the thread.Message ID: @.***>

AKjork commented 1 month ago

The problem is when pvpower starts producing and is more than the houseload it start to show positive Numbers. My house always have a load even if pvpower covers it. IMG_6421 IMG_6422

AKjork commented 1 month ago

Now when pvpower start to ramp up you can see that the loadvalue is not correct. IMG_6425 IMG_6424