TimPaterson / Fusion360-Batch-Post

Fusion add-in to post all CAM setups at once, optionally dividing them into folders.
The Unlicense
132 stars 26 forks source link

Failed to post: Masso.cps Onfinity Foreman #59

Closed DeadspaceDan closed 1 year ago

DeadspaceDan commented 1 year ago

Error: 0 files were written. 1 Setups were skipped due to error: Failed on setup Split Enclosure 500: Fusion 360 reported an exception: 3 : Cannot locate the simple error log generated from the Post Processing.

Using Masso V3 Touch and their provided F360 Post: Masso.cps

TimPaterson commented 1 year ago

I ran a quick test using masso.cps on a small project and it worked OK. Make sure you can post with the built-in F360 command -- it will give you better error reporting if there's a problem.

DeadspaceDan commented 1 year ago

I am not sure what you mean. I have generated cut files from F360 just fine, but when i try pressing the Process All button the above error comes up and no output. I tried Processing Individual files, and several other options in Advanced but it all triggers the same error message. I am on a Mac if that helps as reference.

TimPaterson commented 1 year ago

On closer inspection, I noticed the error message does not include the operation it was on when it failed. This should only be able to happen when the Use individual operations option (under Personal Use) is not checked. Are you using the free version of F360 or a paid/educational version?

DeadspaceDan commented 1 year ago

/facepalm I thought i had tried it both ways. However it worked fine with i attempted it again with "Use individual operations" selected .. Well thank you for this great piece of software!