Balancing abormality #10

Closed BobbyBleacher closed 4 years ago

BobbyBleacher commented 4 years ago

See the screenshot there, Cells 20 and 21 keep bouncing back and forth between unusually high and low values. Unsure of the cause. Not documentation found to support this behavior. Screenshot 2019-09-20 16 31 13

BobbyBleacher commented 4 years ago

If anyone else sees this, I found out what it probably is.

It's what happens when there is a bad connection to a cell, it senses a common mode voltage of two cells split between the two readings... ((4.87 + 2.57)/2) = 3.72

Tom-evnut commented 4 years ago

Alot of issues happen due to faulty wiring it is a pain to track down.