Closed stxShadow closed 4 years ago
Thanks for the catch, for got a few “Break;” after case declarations.
From: stxShadow notifications@github.com Sent: Sunday, March 22, 2020 8:30:01 PM To: tomdebree/TeslaBMSV2 TeslaBMSV2@noreply.github.com Cc: Subscribed subscribed@noreply.github.com Subject: [tomdebree/TeslaBMSV2] wrong value reset in battery settings menu (#18)
If i set a value for "h" -> "j" will be reset to "0"
h - Discharge Current Taper Offset: 300mV j - Discharge Current Temperature Derate : 40.00C
h 200
after that:
h - Discharge Current Taper Offset: 200mV j - Discharge Current Temperature Derate : 0.00C
— You are receiving this because you are subscribed to this thread. Reply to this email directly, view it on GitHubhttps://eur05.safelinks.protection.outlook.com/?url=https%3A%2F%2Fgithub.com%2Ftomdebree%2FTeslaBMSV2%2Fissues%2F18&data=02%7C01%7C%7Cbcd009e2c1ff4428e36508d7ce9fcc3d%7C84df9e7fe9f640afb435aaaaaaaaaaaa%7C1%7C0%7C637205058020922201&sdata=RoE1DqZCMhOdOk%2Bc27tiOmSZxhX6cPtNeMxyGod1oqo%3D&reserved=0, or unsubscribehttps://eur05.safelinks.protection.outlook.com/?url=https%3A%2F%2Fgithub.com%2Fnotifications%2Funsubscribe-auth%2FAGFPAFWZNXQZX3CMRG7KOTTRIZYMTANCNFSM4LRNTIJA&data=02%7C01%7C%7Cbcd009e2c1ff4428e36508d7ce9fcc3d%7C84df9e7fe9f640afb435aaaaaaaaaaaa%7C1%7C0%7C637205058020932196&sdata=FGfjORsIqeo0OklFYqOisr5DS0WfNx%2BuRgLhr1ktuSY%3D&reserved=0.
You are welcome :)
Hope you got my mail to you gmail account too ? Regarding SOC and Victron ESS.
If i set a value for "h" -> "j" will be reset to "0"
h - Discharge Current Taper Offset: 300mV
j - Discharge Current Temperature Derate : 40.00C
h 200
after that:
h - Discharge Current Taper Offset: 200mV
j - Discharge Current Temperature Derate : 0.00C