Closed alan890104 closed 7 months ago
@ipromise2324 needs your help
@ipromise2324 needs your help
ok! I will test this scenario.
After writing test about issue12, the operation fail as it should be.(Due to remain_scale of alarm10 is 0). Please @alan890104 and @WaterSo0910 review this test case
We need to carry out a step-by-step test under the following scenario:
10
, where bothbase_asset_scale
andquote_asset_scale
are set to2
. (remain_scale: 2
)timeKeeper A
invokes the wind method on alarm10
, reducingbase_asset_scale
to1
and elevatingquote_asset_scale
to3
. (remain_scale: 1
)timeKeeper B
also triggers the wind method for alarm10
, this time elevatingbase_asset_scale
back to2
and reducingquote_asset_scale
to2
. (remain_scale: 0
)timeKeeper C
attempts to engage the wind method on alarm10
, the operation fails due to a remaining scale of 0.