Liquid reservoir ignoring max Limit #37

Closed XXilay closed 1 year ago

XXilay commented 1 year ago

Basically just limiting the liquid reservoir to less than 99T will still make it fill up past that limit till 99t

Steps to reproduce the behavior: Make a liquid reservoir , connect a pipe to both input and output sides and then limit it.

There are no Debug Logs in the Steam ONI folders from what I found

Heres the screenshot using 10T of liquid limit: https://imgur.com/a/HJy0Ykl

Desktop (please complete the following information):

Player.log

Truinto commented 1 year ago

That works as intended. The slider sets the logic output and instructs dupes on how much they can store there. Pipes ignore those limitations. If this behavior has been changed since I played the game, then I am not aware of it.