Closed rjanke20 closed 6 years ago
I'm taking the statistical output button off the UI for EPANET, as the statistics report is a SWMM thing. However that error 422 needs to be investigated further, as it appears to be a problem with the EPANET output wrapper.
see also issue #110
@rjanke20 The statistic reporting is for SWMM, evidently trying this on EPANET's output will lead to error. So, removing its access from SWMM's UI should address this issue.
Nothing happens, if no statistic is chosen (Project Tab/Options/Times). If statistic is chosen, e.g., "Maximum", then error message, "SWMM output error calling ENR_newOutValueSeries: EPANET output error #422". Additionally, "Run was successful" status is given.