Issue122 battery model #125

Closed ctib closed 6 years ago

ctib commented 6 years ago

new BaseClasses.Battery as partial model for BatterySimple and BatteryComplex added 2 data sets for Lead Acid batteries and added new parameter p ("Peukert Coefficient") to calculate variable capacity at various loads added a_mcr (maximum charge rate) to reduce charge rate at 80% SOC