new BaseClasses.Battery as partial model for BatterySimple and BatteryComplex
added 2 data sets for Lead Acid batteries and
added new parameter p ("Peukert Coefficient") to calculate variable capacity at various loads
added a_mcr (maximum charge rate) to reduce charge rate at 80% SOC
new BaseClasses.Battery as partial model for BatterySimple and BatteryComplex added 2 data sets for Lead Acid batteries and added new parameter p ("Peukert Coefficient") to calculate variable capacity at various loads added a_mcr (maximum charge rate) to reduce charge rate at 80% SOC