Good evening,

I found its firmware for the T962 reflow oven. I own a T962A, the hardware is identical, but has 4 infrared lamps.

Can your firmware be used for the T962A oven?

Is there a preheating in the latest firmware version?

Thanks in advance and I hope in your answer.

A greeting

wulfmans commented 6 years ago

I have an A version works fine.

On 5/18/2018 2:16 PM, signolo wrote:

Good evening,

I found its firmware for the T962 reflow oven. I own a T962A, the hardware is identical, but has 4 infrared lamps.

Can your firmware be used for the T962A oven?

Is there a preheating in the latest firmware version?

Thanks in advance and I hope in your answer.

A greeting

— You are receiving this because you are subscribed to this thread. Reply to this email directly, view it on GitHub https://github.com/UnifiedEngineering/T-962-improvements/issues/144, or mute the thread https://github.com/notifications/unsubscribe-auth/ACza7QPJ9l7NlyOO6splNg0ZFbIOYaDlks5tzzoXgaJpZM4UFXe2.

signolo commented 6 years ago

Is there a preheating in the latest firmware version?

I have an A version works fine.

radensb commented 6 years ago

Is there a preheating in the latest firmware version?

There is a bake option, if that's what you mean. It allows you to get the ovens internal temperature to a specified temp before you run the profile, which usually includes 20-30 seconds of "preheat" time before the ramp-up to the soak stage, but that 20-30 seconds will be insufficient to heat the ovens internals to the proper temperature.

Typically, I use the bake mode to get the oven to a stable 50C-60C, then run a dry run of my desired profile with a thermocouple on a spare PCB. If all looked good with the temp curves, I set the loaded PCB in and run the profile again. Doing this, I get excellent results every time.

PiquantJason commented 6 years ago

Hello All,

I have this unit and its blowing fuses. I checked the leads feeding down to the lamps and it's basically a dead short.

Any thoughts?

What should it read?