Handled alarm_memory callback #106

Open jimboca opened 2 months ago

jimboca commented 2 months ago

Not actually sure what this means? Does it mean there was an alarm condition, and it must be cleared? How to clear it?

2024-06-18 08:08:06,743 ELK-3857   udi_interface      WARNING  Area:callback: area_1:Area 1: Unknown callback alarm_memory=True
2024-06-18 08:11:17,927 ELK-3857   udi_interface      WARNING  Area:callback: area_1:Area 1: Unknown callback alarm_memory=False

4.37 Alarm Memory Update (AM) Command sent by M1 to inform User Interfaces that an alarm memory is present and must be cleared before an arm command will arm the system. 0CAMSSSSSSSSCC 0A – Length as ASCII hex AM – Alarm Memory Message Command SSSSSSSS – Alarm Memory for each of 8 Areas CC – Checksum S=0 No Alarm Memory S=1 Alarm Memory Present