UtilitechAS / amsreader-firmware

ESP8266 and ESP32 compatible firmware to read, interpret and publish data to MQTT from smart electrical meters, both DLMS and DSMR is supported
Other
389 stars 73 forks source link

Error in sensor configuration for two of the HA MQTT sensors #798

Closed StarkJohan closed 5 months ago

StarkJohan commented 5 months ago

Low severity "bug".

There's an error in sensor configuration for two of the HA MQTT sensors. The warning from the HA log describes the issue as well as the solution pretty clearly as can be seen below.

_Entity sensor.kamstrup_threshold (<class 'homeassistant.components.mqtt.sensor.MqttSensor'>) is using state class 'measurement' which is impossible considering device class ('energy') it is using; expected None or one of 'total_increasing', 'total'; Please update your configuration if your entity is manually configured, otherwise create a bug report at https://github.com/home-assistant/core/issues?q=is%3Aopen+is%3Aissue+label%3A%22integration%3A+mqtt%22 Entity sensor.kamstrup_max (<class 'homeassistant.components.mqtt.sensor.MqttSensor'>) is using state class 'measurement' which is impossible considering device class ('energy') it is using; expected None or one of 'totalincreasing', 'total'; Please update your configuration if your entity is manually configured, otherwise create a bug report at https://github.com/home-assistant/core/issues?q=is%3Aopen+is%3Aissue+label%3A%22integration%3A+mqtt%22

rogerthn2019 commented 5 months ago

+1

2024-05-23 16:34:22.153 WARNING (MainThread) [homeassistant.components.sensor] Entity sensor.ams_cf58_threshold (<class 'homeassistant.components.mqtt.sensor.MqttSensor'>) is using state class 'measurement' which is impossible considering device class ('energy') it is using; expected None or one of 'total_increasing', 'total'; Please update your configuration if your entity is manually configured, otherwise create a bug report at https://github.com/home-assistant/core/issues?q=is%3Aopen+is%3Aissue+label%3A%22integration%3A+mqtt%22 2024-05-23 16:34:22.154 WARNING (MainThread) [homeassistant.components.sensor] Entity sensor.ams_cf58_max (<class 'homeassistant.components.mqtt.sensor.MqttSensor'>) is using state class 'measurement' which is impossible considering device class ('energy') it is using; expected None or one of 'total_increasing', 'total'; Please update your configuration if your entity is manually configured, otherwise create a bug report at https://github.com/home-assistant/core/issues?q=is%3Aopen+is%3Aissue+label%3A%22integration%3A+mqtt%22