VCVRack / AudibleInstruments

VCV Rack plugin based on Mutable Instruments Eurorack modules
https://vcvrack.com/AudibleInstruments.html
Other
387 stars 84 forks source link

Segment Generator does not follow the voltage standards #75

Open rubyglow opened 5 years ago

rubyglow commented 5 years ago

OS: MacOS Sierra 10.12.6 Rack version: 0.6.2c Audible Instruments version: Latest from plugin manager Engine and audio sample rate: 44.1 KHZ

Expected:

A segment in LFO mode at default settings (CV IN == 0V) is expected to run at 120 BPM, according to the Rack voltage standards.

Actual:

It actually runs at 122.7 BPM. To get exactly 120 BPM it takes a CV value of -0.03 V.

This was discovered by user rsmus7 in the community forum on this post and confirmed by Adrian Likins and myself.

To reproduce:

In the same post I have a picture with very clear reproduction here

AndrewBelt commented 5 years ago

Send a PR?